EUVIMEDEUVIMED entdecken
Fallbericht

Balloon Trapping Technique With a Guide Extension Catheter for Retrieval of a Stuck Coronary Guidewire: A Case Report

Taishi Fukushima iD, Masataka Yoshinaga iD, Takashi Muramatsu, Kenya Nasu

Catheterization and Cardiovascular Interventions · 2025-10 · 106 (4) · 2601-2606

DOI: 10.1002/ccd.70104 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 19.08.2025. Verfasst von Taishi Fukushima und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Nagoya University, Nagoya, Japan. Hauptthemen laut MEDLINE: Angioplasty, Balloon, Coronary, Cardiac Catheters, Coronary Occlusion, Device Removal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 6 Literaturangaben. Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Guidewire entrapment beneath a coronary stent is an uncommon but potentially serious complication of percutaneous coronary intervention. Forcible traction of the stuck guidewire may cause structural breakdown of guidewire or stent, potentially resulting in thrombus formation or vessel injuries. We report a case of in‐stent chronic total occlusion of the left anterior descending artery. After deployment of a drug‐eluting stent in the overlapping fashion, the jailed guidewire in a diagonal branch could not be retrieved using standard techniques, such as advancing a microcatheter or small‐balloon close to the stent. Therefore, we advanced a 5 Fr guide extension catheter (GEC) over the jailed guidewire, positioning it close to the deployed stent. A balloon catheter was inflated alongside the jailed guidewire to trap and fix it within the GEC. This assembly—guidewire, balloon, and GEC—could be removed smoothly without stent deformation or vessel injury. To our knowledge, this is the first report of entrapped guidewire successfully retrieved with balloon trapping technique using a GEC. This technique provides controlled countertraction, minimizes the risk of complications, and may serve as a reproducible bailout option when conventional methods fail to retrieve the stuck guidewire.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Angioplasty, Balloon, CoronaryCardiac CathetersCoronary OcclusionDevice RemovalPercutaneous Coronary InterventionHumansCoronary AngiographyDrug-Eluting StentsEquipment DesignTreatment Outcome

Stichwörter der Autor:innen

bailout techniquechronic total occlusioncomplicationguidewire entrapmentpercutaneous coronary intervention

Autor:innen und Institutionen

  • Department of Cardiology, Nagoya University, Nagoya, Japan.
  • Department of Cardiology, Fujita Health University Bantane Hospital, Nagoya, Japan.
  • Department of Cardiology, Fujita Health University Hospital, Toyoake, Japan.
  • Department of Cardiology, Mie Heart Center, Mie, Japan.

ORCID-Profile: Taishi Fukushima, Masataka Yoshinaga

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Fukushima, T., Yoshinaga, M., Muramatsu, T., & Nasu, K. (2025). Balloon Trapping Technique With a Guide Extension Catheter for Retrieval of a Stuck Coronary Guidewire: A Case Report. Catheterization and Cardiovascular Interventions, 106(4), 2601-2606. https://doi.org/10.1002/ccd.70104

Vancouver

Fukushima T, Yoshinaga M, Muramatsu T, Nasu K. Balloon Trapping Technique With a Guide Extension Catheter for Retrieval of a Stuck Coronary Guidewire: A Case Report. Catheterization and Cardiovascular Interventions. 2025;106(4):2601-2606. doi:10.1002/ccd.70104

BibTeX
@article{Fukushima2025,
  author = {Fukushima, Taishi and Yoshinaga, Masataka and Muramatsu, Takashi and Nasu, Kenya},
  title = {Balloon Trapping Technique With a Guide Extension Catheter for Retrieval of a Stuck Coronary Guidewire: A Case Report},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  volume = {106},
  number = {4},
  pages = {2601--2606},
  doi = {10.1002/ccd.70104}
}
Kostenlos starten →