Vergleichsstudie in Catheterization and Cardiovascular Interventions, 2025. Written by Rim Kasem Ali Sliman and 5 co-authors. Institution: Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel. Major MEDLINE topics: Transcatheter Aortic Valve Replacement, Aortic Valve Stenosis, Heart Valve Prosthesis, Aortic Valve. Cited 1 times so far (Crossref); 23 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: The authors received no specific funding for this work..

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Optimal projection views during transcatheter aortic valve implantation (TAVI) procedures are critical for procedural success and patient outcomes.

Aims

This study investigated the influence of 3‐cusp view orientation—line of alignment (LOA) versus non‐LOA—on procedural outcomes in patients undergoing TAVI with contemporary transcatheter heart valves.

Methods

This retrospective analysis included 421 consecutive patients with severe symptomatic aortic stenosis who underwent transfemoral TAVI at a single center between March 2019 and December 2023. Patients received either SAPIEN 3 ( n = 140) or CoreValve Evolut R/PRO ( n = 281) prostheses and were classified as having either LOA ( n = 312, 74.1%) or non‐LOA ( n = 109, 25.9%) projection based on pre‐procedural computed tomography. Primary endpoints included device success according to VARC‐2 criteria, post‐procedural aortic regurgitation, and 30‐day clinical outcomes. Multivariate logistic regression analyses were performed to identify independent predictors of device success, post‐procedural hemodynamics, and the need for permanent pacemaker implantation.

Results

Non‐LOA patients had larger annulus dimensions (461.37 ± 83.52 vs. 441.16 ± 80.83 mm², p = 0.03), higher calcium burden (3072.26 ± 1524.36 vs. 2646.0 ± 1189.11 AU, p = 0.01), and required more contrast (179.99 ± 67.12 vs. 161.94 ± 64.7 ml, p = 0.01). Multivariate analysis revealed that aortic valve calcium score was the only independent predictor of device success ( p = 0.018), while LOA orientation showed no significant association ( p = 0.971). Valve type was the primary determinant of post‐procedural hemodynamics (SAPIEN 3 superior, p = 0.025), and prior bundle branch block was the strongest pacemaker predictor ( p = 0.005). Device success (94.81% vs. 95.88%, p = 0.86) and safety outcomes were comparable between groups.

Conclusions

While LOA orientation creates anatomical differences, it doesn't change fundamental treatment decisions—calcium burden and valve type remain the primary determinants of outcomes. LOA status should inform procedural planning through enhanced contrast management and risk‐stratified surveillance, without compromising fundamental treatment decisions. Contemporary TAVI procedures demonstrate excellent safety and efficacy across both types of projections.

Subjects

MeSH terms (MEDLINE)

Transcatheter Aortic Valve ReplacementAortic Valve StenosisHeart Valve ProsthesisAortic ValveHumansMaleRetrospective StudiesFemaleTreatment OutcomeAged, 80 and overProsthesis DesignAgedRisk FactorsPredictive Value of TestsTime FactorsHemodynamicsSeverity of Illness IndexAortic Valve InsufficiencyRisk AssessmentRecovery of Function

Author keywords

3‐cusp viewaortic root anatomyaortic stenosiscomputed tomographytranscatheter aortic valve implantation (TAVI)valve deployment, anatomical variation

Authors and institutions

  • Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.
  • Department of Cardiovascular Medicine, Lady Davis Carmel Medical Center, Haifa, Israel.

ORCID profiles: Amnon Eitan

Funding

  • The authors received no specific funding for this work.

Cite

APA

Kasem Ali Sliman, R., Eitan, A., Zisman, K., Avidan, Y., Aker, A., & Sliman, H. (2025). Three‐Cusp View Orientation in TAVI: Evaluating LOA Versus Non‐LOA Impact on Outcomes With Contemporary Valve Prostheses. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70087

Vancouver

Kasem Ali Sliman R, Eitan A, Zisman K, Avidan Y, Aker A, Sliman H. Three‐Cusp View Orientation in TAVI: Evaluating LOA Versus Non‐LOA Impact on Outcomes With Contemporary Valve Prostheses. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70087

BibTeX
@article{KasemAliSliman2025,
  author = {Kasem Ali Sliman, Rim and Eitan, Amnon and Zisman, Keren and Avidan, Yuval and Aker, Amir and Sliman, Hussein},
  title = {Three‐Cusp View Orientation in TAVI: Evaluating LOA Versus Non‐LOA Impact on Outcomes With Contemporary Valve Prostheses},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.70087}
}
Start for free →