Fachartikel in der Zeitschrift Asian Cardiovascular and Thoracic Annals, 2025. Verfasst von Hideki Kitamura und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Nagoya Heart Center, Nagoya, Japan. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Transcatheter Aortic Valve Replacement, Aortic Valve, Aortic Valve Stenosis. Die Arbeit nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Valve-in-valve transcatheter aortic valve implantation (TAVI) has been confirmed as effective. Additionally, aortic annular enlargement has been advocated to avoid small valves at initial surgery, because they can cause patient-prosthesis mismatch, particularly after TAVI in surgical aortic valve replacement (SAVR). However, results remain unclear for TAVI with a small initial aortic valve in small body size patients. The purpose is to clarify the TAVI valve function after a small surgical valve in a small body population.

Methods

We retrospectively screened 52 cases of TAVI in SAVR performed from 2018 to 2024. Post-procedural TAVI valve function and post-procedural New York Heart Association (NYHA) functional class were examined.

Results

Of 52 TAVI in SAVR cases, 16 cases had a 19 mm initial surgical aortic valve, and 19 cases had 21 mm. The mean age of these 35 cases was 83.1 years old and 20% were male. Mean body surface area was 1.39 cm 2 . After TAVI in SAVR in 35 cases, the mean pressure gradient was 18.5 mmHg, and the effective orifice area (EOA) was 1.10 cm 2 . Even after 19-mm SAVR, the mean pressure gradient was 13.4 mmHg, and EOA was 1.13 cm 2 , excluding 3 cases of off-label use and 3 cases of balloon-expandable valves. At the time of last follow-up, 86.2% of survivors remained in NYHA I or II.

Conclusions

Self-expanding TAVI in a certain type of SAVR provided sufficient valve function in a population with small body size, even after small-sized initial surgical prostheses. Surgeons need to ensure that the proper type and size of surgical prosthesis are implanted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisTranscatheter Aortic Valve ReplacementAortic ValveAortic Valve StenosisBody SizeHeart Valve Prosthesis ImplantationHumansMaleRetrospective StudiesFemaleAged, 80 and overTreatment OutcomeProsthesis DesignAgedTime FactorsRecovery of FunctionRisk FactorsHemodynamics

Stichwörter der Autor:innen

Valve-in-valvesmall body patientssurgical aortic valve replacementtranscatheter aortic valve insertion

Autor:innen und Institutionen

  • Department of Cardiovascular Surgery, Nagoya Heart Center, Nagoya, Japan.
  • Department of Cardiology, Nagoya Heart Center, Nagoya, Japan.
  • Department of Cardiology, Toyohashi Heart Center, Toyohashi, Japan.

ORCID-Profile: Hideki Kitamura

Zitieren

APA

Kitamura, H., Fukumoto, Y., Imamura, Y., Kagase, A., & Yamamoto, M. (2025). Transcatheter aortic valve implantation in small surgical aortic prosthesis for small body size patients. Asian Cardiovascular and Thoracic Annals. https://doi.org/10.1177/02184923251331338

Vancouver

Kitamura H, Fukumoto Y, Imamura Y, Kagase A, Yamamoto M. Transcatheter aortic valve implantation in small surgical aortic prosthesis for small body size patients. Asian Cardiovascular and Thoracic Annals. 2025. doi:10.1177/02184923251331338

BibTeX
@article{Kitamura2025,
  author = {Kitamura, Hideki and Fukumoto, Yuichiro and Imamura, Yusuke and Kagase, Ai and Yamamoto, Masanori},
  title = {Transcatheter aortic valve implantation in small surgical aortic prosthesis for small body size patients},
  journal = {Asian Cardiovascular and Thoracic Annals},
  year = {2025},
  doi = {10.1177/02184923251331338}
}
Kostenlos starten →