EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

A Printed Hydrogel Hybrid Electronic System With Thermoresponsive Adhesion for Neurophysiological Monitoring

Bo Pang, Ganguang Yang, Jiacheng Wen, Hangyu Gong, Caixin Gong, Yuqi Qiu, Zhixin Wang, Qingyang Zheng, Sen Zhou, Tianzhao Bu, Jia Tian, Zhouping Yin and 2 more

Advanced Science · 2026-09 · 13 (54)

DOI: 10.1002/advs.76396 ↗

At a glance

Journal article in Advanced Science, published online on 2026-06-29. Written by Bo Pang and 13 co-authors. Institution: Flexible Electronics Research Center, State Key Laboratory of Intelligent Manufacturing Equipment and Technology, School of Mechanical Science and En…. Major MEDLINE topics: Hydrogels, Neurophysiological Monitoring. Cited 2 times so far (Crossref); 50 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities, STAR Project by the School of Mechanical Science and Engineering of Huazhong University of Science and Technology.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Neurological disorders severely impair the daily life of patients, necessitating precise assessments of neural conduction pathway damage to guide effective diagnosis and treatment. However, current clinical neurodiagnostic equipment is expensive, bulky, and restricted to hospital settings. Furthermore, the rigid nature and low adhesion of conventional electrodes lead to the acquisition of low‐quality neurophysiological signals. Here, we develop a soft hybrid electronic system assembled with printed responsive hydrogel electrodes. By synthesizing thermoresponsive hydrogel microsphere inks, we achieve rapid direct‐printed patterning of interface layers. Based on a thermally triggered hydration‐dehydration strategy of hydrogel microspheres, the hydrogel electrodes demonstrate customizable adhesion, enabling intimate integration with skin for high‐fidelity signal acquisition and gentle detachment after monitoring. Through hydrogel interface modification, on‐skin electrodes also show excellent charge injection capability for stimulation and improved signal‐to‐noise ratio (SNR). The integration of hydrogel patches with the hybrid electronic system enables high‐frequency and high‐fidelity acquisition of subtle neural conduction signals. We further apply this system to assess injuries to the median and ulnar nerves in clinical cases, realizing accurate diagnosis of neural impairment while ensuring customized adhesion regulation. This user‐friendly system holds great promise as a low‐cost and portable diagnostic platform for telemedicine, home‐based care, and clinical settings.

Subjects

MeSH terms (MEDLINE)

HydrogelsNeurophysiological MonitoringHumansElectrodesNeural Conduction

Author keywords

direct printingneurophysiological monitoringsoft hybrid electronicsthermoresponsive hydrogel interfaces

Substances

Hydrogels

Authors and institutions

  • Flexible Electronics Research Center, State Key Laboratory of Intelligent Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China.
  • Department of Hand Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • School of Integrated Circuits, Huazhong University of Science and Technology, Wuhan, Hubei, China.

ORCID profiles: Hao Wu

Funding

  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities
  • STAR Project by the School of Mechanical Science and Engineering of Huazhong University of Science and Technology
  • Young Top-notch Talent Cultivation Program of Hubei Province
  • Taihu Lake Innovation Fund for Future Technology, HUST
  • Hubei Science & Technology Major Projec

Cite

APA

Pang, B., Yang, G., Wen, J., Gong, H., Gong, C., Qiu, Y., Wang, Z., Zheng, Q., Zhou, S., Bu, T., Tian, J., Yin, Z., Liu, Y., & Wu, H. (2026). A Printed Hydrogel Hybrid Electronic System With Thermoresponsive Adhesion for Neurophysiological Monitoring. Advanced Science, 13(54). https://doi.org/10.1002/advs.76396

Vancouver

Pang B, Yang G, Wen J, Gong H, Gong C, Qiu Y, et al. A Printed Hydrogel Hybrid Electronic System With Thermoresponsive Adhesion for Neurophysiological Monitoring. Advanced Science. 2026;13(54). doi:10.1002/advs.76396

BibTeX
@article{Pang2026,
  author = {Pang, Bo and Yang, Ganguang and Wen, Jiacheng and Gong, Hangyu and Gong, Caixin and Qiu, Yuqi and Wang, Zhixin and Zheng, Qingyang and Zhou, Sen and Bu, Tianzhao and Tian, Jia and Yin, Zhouping and Liu, Yutian and Wu, Hao},
  title = {A Printed Hydrogel Hybrid Electronic System With Thermoresponsive Adhesion for Neurophysiological Monitoring},
  journal = {Advanced Science},
  year = {2026},
  volume = {13},
  number = {54},
  doi = {10.1002/advs.76396}
}
Start for free →