A soft electrode array with reconfigurable hydrogel interfaces for high-fidelity neurophysiological monitoring during craniotomy
Proceedings of the National Academy of Sciences · 2026
DOI: 10.1073/pnas.2533145123 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the National Academy of Sciences, 2026. Verfasst von Ganguang Yang und 14 weiteren Autor:innen. Beteiligte Einrichtung: Flexible Electronics Research Center, State Key Laboratory of Intelligent Manufacturing Equipment and Technology, School of Mechanical Science and En…. Hauptthemen laut MEDLINE: Craniotomy, Hydrogels, Neurophysiological Monitoring. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: MOST | National Natural Science Foundation of China (NSFC), Agency for Science, Technology and Research (A*STAR).
Abstract (Originalsprache)
Achieving accurate monitoring of electrophysiological activity from the brain cortex is critical for preventing postoperative neurological deficits during craniotomy. However, current technologies face profound challenges in enabling consistent high-quality neural signal acquisition due to complex intracranial environments (e.g., wet/fragile brain surfaces and surgical instrument interference). Here, we develop a soft electrode array with reconfigurable hydrogel interfaces for sustainable high-fidelity monitoring of electrophysiological states from the functional brain cortex throughout neurosurgical procedures. Specifically, we propose a solution-triggered reconfiguration strategy to implement the repeated disassembly/replacement of hydrogel interface layers on electrodes, ensuring consistently superior recording and stimulation properties. Furthermore, through modification with cationic hydrogel microspheres, the hydrogel interface demonstrates strengthened wet adhesion and antiswelling performances, creating robust hydrogel/brain coupling to minimize motion artifacts. In craniotomy of animal models, the electrode array maintains low impedance and high signal-to-noise ratio during repeated repositioning tests through hydrogel interface reconfiguration. In traumatic brain injury models, the electrode array can record consistent high-quality somatosensory evoked potential with dynamic tracking of potential amplitude and latency changes in sensory areas. Quantitative assessments in nerve block experiments verify that the soft electrode array can efficiently elicit motor evoked potentials in motor areas with low stimulation currents. The proposed soft electrode array represents a promising platform for sustainable high-fidelity electrophysiological monitoring. The hydrogel interface design strategy provides an effective approach for developing reconfigurable devices in biomedical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Flexible Electronics Research Center, State Key Laboratory of Intelligent Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, Hubei…
- Department of Neurology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430022, China.
- Department of Materials Science and Engineering, National University of Singapore, Singapore 117575, Singapore.
- Institute for Health Innovation and Technology, National University of Singapore, Singapore 117599, Singapore.
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore 119276, Singapore.
- The N.1 Institute for Health, National University of Singapore, Singapore 117456, Singapore.
ORCID-Profile: Hangyu Gong, Haiyan Qiao, Zhouping Yin, Changsheng Wu, Hao Wu
Förderung
- MOST | National Natural Science Foundation of China (NSFC)
- Agency for Science, Technology and Research (A*STAR)
Zitieren
APA
Yang, G., Pang, B., Gong, H., Qiu, Y., Gong, C., Zhou, S., Zheng, Q., Wang, Z., Bu, T., Xu, S., Luo, X., Qiao, H., Yin, Z., Wu, C., & Wu, H. (2026). A soft electrode array with reconfigurable hydrogel interfaces for high-fidelity neurophysiological monitoring during craniotomy. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.2533145123
Vancouver
Yang G, Pang B, Gong H, Qiu Y, Gong C, Zhou S, et al. A soft electrode array with reconfigurable hydrogel interfaces for high-fidelity neurophysiological monitoring during craniotomy. Proceedings of the National Academy of Sciences. 2026. doi:10.1073/pnas.2533145123
BibTeX
@article{Yang2026,
author = {Yang, Ganguang and Pang, Bo and Gong, Hangyu and Qiu, Yuqi and Gong, Caixin and Zhou, Sen and Zheng, Qingyang and Wang, Zhixin and Bu, Tianzhao and Xu, Shabei and Luo, Xiang and Qiao, Haiyan and Yin, Zhouping and Wu, Changsheng and Wu, Hao},
title = {A soft electrode array with reconfigurable hydrogel interfaces for high-fidelity neurophysiological monitoring during craniotomy},
journal = {Proceedings of the National Academy of Sciences},
year = {2026},
doi = {10.1073/pnas.2533145123}
}
EUVIMED