Real‐Time 3D Ultrasound Imaging with an Ultra‐Sparse, Low Power Architecture
Advanced Healthcare Materials · 2026-04 · 15 (16)
DOI: 10.1002/adhm.202505310 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, online erschienen am 29.01.2026. Verfasst von Colin Marcus und 9 weiteren Autor:innen. Beteiligte Einrichtung: Media Lab, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Conformable Piezoelectrics for Soft Tissue Imaging.
Abstract (Originalsprache)
Effective resource‐constrained volumetric ultrasound imaging requires compact, low‐power systems capable of wide‐angle real‐time 3D imaging to accommodate small changes in placement by the operator. However, obtaining such images requires an excessive O(N 2 ) channel count, bulky electronics, and high power consumption. We introduce an end‐to‐end system architecture to enable high‐resolution, real‐time 3D ultrasound imaging in a portable form factor. We present: a convolutional optimally distributed array (CODA) geometry that drastically reduces the number of elements (from 1024 to 128), a novel chirped data acquisition (cDAQ) architecture that enhances imaging depth while operating with a 25.3 dB lower transmit amplitude than a pulsed system, and an associated new signal processing methodology. We experimentally demonstrate our system's ability to perform deep (> 11 cm), high axial resolution (< 600 µm), and wide‐angle (57°) imaging, while simultaneously reducing power consumption (29.6x reduction) and drive voltage (18 V). We validated our system in vitro and further performed in vivo human trials, demonstrating the ability to detect both tumors and cysts in breast tissue. This new architectural approach will unlock a new class of medical devices with enhanced diagnostic and long‐term monitoring capabilities and open up future wearable designs of real‐time 3D ultrasound systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Media Lab, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
- Division of Surgical Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
ORCID-Profile: Md Osman Goni Nayeem, Canan Dagdeviren
Förderung
- Conformable Piezoelectrics for Soft Tissue Imaging
Zitieren
APA
Marcus, C., Nayeem, M. O. G., Shah, A., Hou, J., Viswanath, S., Eusebio, M., Sadat, D., Chandrakasan, A. P., Ozmen, T., & Dagdeviren, C. (2026). Real‐Time 3D Ultrasound Imaging with an Ultra‐Sparse, Low Power Architecture. Advanced Healthcare Materials, 15(16). https://doi.org/10.1002/adhm.202505310
Vancouver
Marcus C, Nayeem MOG, Shah A, Hou J, Viswanath S, Eusebio M, et al. Real‐Time 3D Ultrasound Imaging with an Ultra‐Sparse, Low Power Architecture. Advanced Healthcare Materials. 2026;15(16). doi:10.1002/adhm.202505310
BibTeX
@article{Marcus2026,
author = {Marcus, Colin and Nayeem, Md Osman Goni and Shah, Aastha and Hou, Jason and Viswanath, Shrihari and Eusebio, Maya and Sadat, David and Chandrakasan, Anantha P and Ozmen, Tolga and Dagdeviren, Canan},
title = {Real‐Time 3D Ultrasound Imaging with an Ultra‐Sparse, Low Power Architecture},
journal = {Advanced Healthcare Materials},
year = {2026},
volume = {15},
number = {16},
doi = {10.1002/adhm.202505310}
}
EUVIMED