Multidimensional RF pulse design using auto‐differentiable spin‐domain optimization and its application to reduced field‐of‐view imaging
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30607 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Jiayao Yang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Imaging, Three-Dimensional, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Siemens Healthineers, NIH HHS, NCI NIH HHS.
Abstract (Originalsprache)
Purpose
Develop a general radiofrequency (RF) pulse design algorithm for the design of three‐dimensional (3D) spatially selective refocusing pulses and explore their potential applications in reduced field‐of‐view imaging.
Methods
Spin‐domain representation was used to describe the effect of RF pulses and to formulate the optimization problem. The implementation was based on an auto‐differentiable simulator. Spatially selective excitation and refocusing pulses for a small regions of interest were designed with consideration of hardware limits and B 0 and B 1 + inhomogeneities. The designed RF pulses were validated in simulation as well as in vivo experiments in brain and prostate on a 3T scanner.
Results
Pulses of short duration (4.15 ms) were designed for 3D tailored excitation and refocusing accounting for B 0 and B 1 + inhomogeneities. The computation time for each design was approximately 7 min. Improved outer‐volume signal suppression in phantom and in vivo spin‐echo imaging experiments was achieved by combining 3D excitation and refocusing pulses compared with using only one 3D pulse. The potential of using tailored 3D pulses to obtain images with higher spatial resolution (1 1 3 mm 3 ) and less distortion with the same scan time was demonstrated by acquiring reduced field‐of‐view 3D images of brain and prostate.
Conclusion
The proposed algorithm jointly optimizes the RF and gradient waveforms given an initial pulse and a desired spin‐domain target pattern. Our approach is broadly applicable to the design of excitation and refocusing pulses and complements existing methods based on describing individual spin isochromatic behavior. Combining 3D excitation and 3D refocusing pulses produced better spatial selectivity than using a combination of one‐dimensional and 3D pulses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan, USA.
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
ORCID-Profile: Jiayao Yang, Jon-Fredrik Nielsen, Jeffrey A Fessler, Yun Jiang
Förderung
- Siemens Healthineers
- NIH HHS
- NCI NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Yang, J., Nielsen, J. F., Fessler, J. A., & Jiang, Y. (2025). Multidimensional RF pulse design using auto‐differentiable spin‐domain optimization and its application to reduced field‐of‐view imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30607
Vancouver
Yang J, Nielsen JF, Fessler JA, Jiang Y. Multidimensional RF pulse design using auto‐differentiable spin‐domain optimization and its application to reduced field‐of‐view imaging. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30607
BibTeX
@article{Yang2025,
author = {Yang, Jiayao and Nielsen, Jon-Fredrik and Fessler, Jeffrey A and Jiang, Yun},
title = {Multidimensional RF pulse design using auto‐differentiable spin‐domain optimization and its application to reduced field‐of‐view imaging},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30607}
}