EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

High-Volume Acquisition Rate Nonlinear Imaging Enables Robust 3-D Ultrasound Localization Microscopy

YiRang Shin, Bing-Ze Lin, Matthew R Lowerison, Qi You, Pengfei Song

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2025-09 · 72 (9) · 1199-1212

DOI: 10.1109/tuffc.2025.3589815 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2025-09. Verfasst von YiRang Shin und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Microscopy, Acoustic. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIDDK NIH HHS, NIBIB NIH HHS, NINDS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

3-D ultrasound localization microscopy (ULM) enables comprehensive mapping of microvascular networks by providing micrometer-scale spatial resolution while avoiding projection errors inherent to 2-D ULM imaging. Current 3-D ULM techniques are based on linear pulse sequences combined with spatiotemporal filtering to distinguish microbubble flow from tissue signals. However, singular-value decomposition (SVD)-based filtering demonstrates poor performance in highly mobile organs, suppressing small vessels with slow blood flow along with tissue signals. While imaging based on nonlinear multipulse sequences can isolate microbubble signals regardless of tissue motion, achieving the high-volume acquisition rates required for 3-D ULM remains technically challenging. Here, we present Fast3D-amplitude modulation (AM) imaging, a 3-D nonlinear imaging sequence that achieves a high-volume acquisition rate (225 Hz) using a single 256-channel ultrasound system with a multiplexed 2-D matrix array. We also introduce a motion rejection algorithm that leverages localized microbubble positions to reject respiratory-induced motion artifacts. Fast3D-AM imaging achieved a superior contrast-to-tissue ratio (CTR) than Fast3D, exhibiting a 6.66-dB improvement in phantom studies. In an in vivo rat study, Fast3D-AM demonstrated higher CTR across all SVD cutoffs compared to Fast3D and preserved both major and microvascular structures in whole-organ kidney imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalMicroscopy, AcousticAnimalsRatsMicrobubblesAlgorithmsPhantoms, ImagingUltrasonographyKidneySignal Processing, Computer-AssistedRats, Sprague-Dawley

Förderung

  • NIDDK NIH HHS
  • NIBIB NIH HHS
  • NINDS NIH HHS
  • National Institute of Diabetes and Digestive and Kidney Diseases
  • Chan Zuckerberg Initiative (CZI) Ben Barres Early Career Acceleration Award
  • National Institute of Neurological Disorders and Stroke
  • National Science Foundation CAREER Award
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Shin, Y., Lin, B. Z., Lowerison, M. R., You, Q., & Song, P. (2025). High-Volume Acquisition Rate Nonlinear Imaging Enables Robust 3-D Ultrasound Localization Microscopy. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2025.3589815

Vancouver

Shin Y, Lin BZ, Lowerison MR, You Q, Song P. High-Volume Acquisition Rate Nonlinear Imaging Enables Robust 3-D Ultrasound Localization Microscopy. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2025. doi:10.1109/tuffc.2025.3589815

BibTeX
@article{Shin2025,
  author = {Shin, YiRang and Lin, Bing-Ze and Lowerison, Matthew R and You, Qi and Song, Pengfei},
  title = {High-Volume Acquisition Rate Nonlinear Imaging Enables Robust 3-D Ultrasound Localization Microscopy},
  journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
  year = {2025},
  doi = {10.1109/tuffc.2025.3589815}
}
Kostenlos starten →