Proton arc therapy reduces the dose delivered to circulating blood compared to intensity‐modulated proton therapy for head‐and‐neck cancer

Sebastian Tattenberg, Peilin Liu iD, Xiaoda Cong, Cornelia Hoehr, Xuanfeng Ding

Journal of Applied Clinical Medical Physics · 2026-11 · 27 (11)

DOI: 10.1002/acm2.70864 ↗

At a glance

Vergleichsstudie in Journal of Applied Clinical Medical Physics, published online on 2026-10-20. Written by Sebastian Tattenberg and 4 co-authors. Institution: Division of Life Sciences, TRIUMF, Vancouver, British Columbia, Canada. Major MEDLINE topics: Proton Therapy, Radiotherapy, Intensity-Modulated, Head and Neck Neoplasms, Radiotherapy Planning, Computer-Assisted. 33 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIH HHS, NCI NIH HHS, National Institutes of Health.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Compared to intensity‐modulated proton therapy (IMPT), proton arc therapy (PAT) has various dosimetric advantages. However, questions have been raised over whether the larger low‐dose bath during PAT may increase radiation‐induced lymphocyte killing, which is correlated with adverse clinical outcomes.

Purpose

The purpose of this study is to quantitatively compare radiation dose delivery to circulating blood during IMPT and PAT.

Methods

For each of 10 head‐and‐neck cancer patients, one IMPT and one PAT treatment plan were created, and the hematological dose (HEDOS) blood dose model was used to simulate radiation dose delivery to circulating blood. HEDOS simulations utilized gantry angle‐wise dose distributions (including for PAT) and considered gantry rotation and energy layer switching as well as irradiation times. Blood dose histograms as well as the mean dose to all simulation blood particles (D mean ) and the dose delivered to the 90% and 10% of blood particles receiving the highest dose (D 90% and D 10% ) were then compared between IMPT and PAT.

Results

For IMPT, blood dose metrics (in the form of mean over all patients ± one standard deviation) were (0.522 ± 0.204)Gy(RBE) for D 90% , (0.563 ± 0.212)Gy(RBE) for D mean , and (0.605 ± 0.219)Gy(RBE) for D 10% . For PAT, D 90% was (0.430 ± 0.184)Gy(RBE), D mean was (0.483 ± 0.195)Gy(RBE), and D 10% was (0.538 ± 0.207)Gy(RBE). The Wilcoxon signed‐rank test indicated statistically significant ( p < 0.05) differences between blood dose metrics of IMPT and PAT for all patients, and IMPT did not increase the percentage of blood particles which received no radiation dose during the delivery of a single treatment fraction.

Conclusions

Compared to IMPT, proton arc therapy was associated with significantly lower radiation dose delivery to circulating blood across a variety of different metrics. Proton arc therapy for head‐and‐neck cancer is therefore not expected to result in higher radiation‐induced killing of circulating lymphocytes compared to IMPT.

Subjects

MeSH terms (MEDLINE)

Proton TherapyRadiotherapy, Intensity-ModulatedHead and Neck NeoplasmsRadiotherapy Planning, Computer-AssistedBloodHumansRadiotherapy DosageOrgans at RiskPrognosis

Author keywords

blood doseproton arc therapyproton therapyradiation‐induced lymphopenia

Authors and institutions

  • Division of Life Sciences, TRIUMF, Vancouver, British Columbia, Canada.
  • Department of Radiation Oncology, William Beaumont University Hospital, Corewell Health, Royal Oak, Michigan, USA.

ORCID profiles: Peilin Liu

Funding

  • NIH HHS
  • NCI NIH HHS
  • National Institutes of Health
  • National Cancer Institute

Cite

APA

Tattenberg, S., Liu, P., Cong, X., Hoehr, C., & Ding, X. (2026). Proton arc therapy reduces the dose delivered to circulating blood compared to intensity‐modulated proton therapy for head‐and‐neck cancer. Journal of Applied Clinical Medical Physics, 27(11). https://doi.org/10.1002/acm2.70864

Vancouver

Tattenberg S, Liu P, Cong X, Hoehr C, Ding X. Proton arc therapy reduces the dose delivered to circulating blood compared to intensity‐modulated proton therapy for head‐and‐neck cancer. Journal of Applied Clinical Medical Physics. 2026;27(11). doi:10.1002/acm2.70864

BibTeX
@article{Tattenberg2026,
  author = {Tattenberg, Sebastian and Liu, Peilin and Cong, Xiaoda and Hoehr, Cornelia and Ding, Xuanfeng},
  title = {Proton arc therapy reduces the dose delivered to circulating blood compared to intensity‐modulated proton therapy for head‐and‐neck cancer},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  volume = {27},
  number = {11},
  doi = {10.1002/acm2.70864}
}
Start for free →