Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von ByongYong Yi und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Proton Therapy, Radiotherapy, Intensity-Modulated, Head and Neck Neoplasms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Noncoplanar plans (NCPs) are commonly used for proton treatment of bilateral head and neck (HN) malignancies. NCP requires additional verification setup imaging between beams to correct residual errors of robotic couch motion, which increases imaging dose and total treatment time. This study compared the quality and robustness of NCPs with those of coplanar plans (CPs). Methods and Materials Under an IRB‐approved study, CPs were created retrospectively for 10 bilateral HN patients previously treated with NCPs maintaining identical beam geometry of the original plan but excluding couch rotations. Plan robustness to the inter‐fractional variation (IV) of both plans was evaluated through the Dose Volume Histograms (DVH) of weekly quality assurance CT (QACT) sets (39 total). In addition, delivery efficiency for both plans was compared using total treatment time (TTT) and beam‐on time (BOT).

Results

No significant differences in plan quality were observed in terms of clinical target volume (CTV) coverage (D95) or organ‐at‐risk (OAR) doses ( p > 0.4 for all CTVs and OARs). No significant advantage of NCPs in the robustness to IV was found over CP, either. Changes in D95 of QA plans showed a linear correlation (slope = 1.006, R 2 > 0.99) between NCP and CP for three CTV data points (CTV1, CTV2, and CTV3) in each QA plan (117 data points for 39 QA plans). NCPs showed significantly higher beam delivery time than CPs for TTT (539 ± 50 vs. 897 ± 142 s; p < 0.001); however, no significant differences were observed for BOT.

Conclusion

NCPs are not more robust to IV than CPs when treating bilateral HN tumors with pencil‐beam scanning proton beams. CPs showed plan quality and robustness similar to NCPs while reduced treatment time (∼6 min). This suggests that CPs may be a more efficient planning technique for bilateral HN cancer proton therapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyRadiotherapy, Intensity-ModulatedHead and Neck NeoplasmsHumansProtonsRetrospective StudiesRadiotherapy Planning, Computer-AssistedRadiotherapy DosageOrgans at Risk

Stichwörter der Autor:innen

head & necknoncoplanar planproton PBS

Substanzen

Protons

Autor:innen und Institutionen

  • Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland, USA.
  • Maryland Proton Treatment Center, Baltimore, Maryland, USA.

ORCID-Profile: ByongYong Yi, Yannick P Poirier, Weiguang Yao, Jason K Molitoris, Mark J Zakhary, Baoshe Zhang, Nrusingh C Biswal, Matthew J Ferris, Sina Mossahebi

Zitieren

APA

Yi, B., Jatczak, J., Deng, W., Poirier, Y. P., Yao, W., Witek, M. E., Molitoris, J. K., Zakhary, M. J., Zhang, B., Biswal, N. C., Ferris, M. J., & Mossahebi, S. (2024). Is noncoplanar plan more robust to inter‐fractional variations than coplanar plan in treating bilateral HN tumors with pencil‐beam scanning proton beams?. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14186

Vancouver

Yi B, Jatczak J, Deng W, Poirier YP, Yao W, Witek ME, et al. Is noncoplanar plan more robust to inter‐fractional variations than coplanar plan in treating bilateral HN tumors with pencil‐beam scanning proton beams?. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14186

BibTeX
@article{Yi2024,
  author = {Yi, ByongYong and Jatczak, Jenna and Deng, Wei and Poirier, Yannick P and Yao, Weiguang and Witek, Matthew E and Molitoris, Jason K and Zakhary, Mark J and Zhang, Baoshe and Biswal, Nrusingh C and Ferris, Matthew J and Mossahebi, Sina},
  title = {Is noncoplanar plan more robust to inter‐fractional variations than coplanar plan in treating bilateral HN tumors with pencil‐beam scanning proton beams?},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14186}
}
Kostenlos starten →