Solid‐state dosimeters have rendered ionization chambers obsolete for routine diagnostic X‐ray quality control
Journal of Applied Clinical Medical Physics · 2026-06 · 27 (6)
DOI: 10.1002/acm2.70657 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 10.06.2026. Verfasst von Allen R Goode und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Medical Imaging, UVA Health, Charlottesville, Virginia, USA. Hauptthemen laut MEDLINE: Quality Control, Radiometry, Quality Assurance, Health Care, Radiation Dosimeters. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Today's diagnostic medical physicist finds a broad variety of instruments available to make the numerous quality control (QC) measurements needed for routine equipment evaluations. One of the distinguishing features of different options is the availability of multi‐purpose solid‐state detectors (SSD) and application‐specific ion chambers (IC) that can be used for measurements of the various modality equipment types. Since these measurements are the “bread and butter” of diagnostic physics work and the foundation of quality and safety for patients, the choice will have profound implications for many aspects of the physicist's work. In this debate, we explore the roles of SSD and IC instruments through the insights and perspectives of two highly experienced and accomplished diagnostic medical physicists.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Medical Imaging, UVA Health, Charlottesville, Virginia, USA.
- Department of Radiology, The Ohio State University, Columbus, Ohio, USA.
- Department of Radiology, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA.
- Department of Radiology, VA Northeast Ohio Healthcare System, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA.
Zitieren
APA
Goode, A. R., Wunderle, K. A., & Jordan, D. W. (2026). Solid‐state dosimeters have rendered ionization chambers obsolete for routine diagnostic X‐ray quality control. Journal of Applied Clinical Medical Physics, 27(6). https://doi.org/10.1002/acm2.70657
Vancouver
Goode AR, Wunderle KA, Jordan DW. Solid‐state dosimeters have rendered ionization chambers obsolete for routine diagnostic X‐ray quality control. Journal of Applied Clinical Medical Physics. 2026;27(6). doi:10.1002/acm2.70657
BibTeX
@article{Goode2026,
author = {Goode, Allen R and Wunderle, Kevin A and Jordan, David W},
title = {Solid‐state dosimeters have rendered ionization chambers obsolete for routine diagnostic X‐ray quality control},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
volume = {27},
number = {6},
doi = {10.1002/acm2.70657}
}
EUVIMED