Quantifying upright positioning accuracy with optical surface tracking in radiotherapy

Yusuke Nomura iD, Sodai Tanaka, Hideyuki Takei, Kinji Maeda, Takuro Takekoshi, Hideki Iwakami, Hirotoshi Takiyama, Minoru Tajiri, Shunsuke Yonai, Hideyuki Mizuno, Yoshiyuki Iwata, Taku Inaniwa und 1 weitere

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70527 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Yusuke Nomura und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba, …. Hauptthemen laut MEDLINE: Patient Positioning, Radiotherapy Planning, Computer-Assisted, Radiotherapy Setup Errors, Head and Neck Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study quantified inter‐ and intra‐fractional setup accuracies in the upright posture and compared them among setups with different immobilization methods.

Methods

Two and four setups were examined for abdominal and head and neck (HN) cancer treatments, respectively. Fifteen asymptomatic volunteers were positioned to a replicated chair of an upright radiotherapy platform with leg immobilization devices, backrest attachments, thermoplastic masks, and vacuum cushions. The 3D positions of the subject body and masks were monitored by calculating 3D point clouds of 26 surface markers from three camera images. The inter‐fractional setup errors were calculated by repeating the same setup five times. The intra‐fractional displacements were evaluated while the subjects remained in the setups for 20 min. These setup errors and displacements were compared among the setups with different immobilization methods. The intra‐fractional displacements were also compared between this study and previous studies in the supine posture.

Results

Inter‐fractional setup errors in the abdominal setups were reduced from 6.6 ± 3.3 to 3.9 ± 1.7 mm by using the masks. The HN setup using both the leg immobilization devices and backrest attachments had the setup errors of 2.9 ± 1.7 mm. This was smaller than the setup errors observed in three other HN setups that did not use either or both of the devices together. Intra‐fractional displacements of these abdominal and HN setups with the immobilization devices were 1.9 ± 1.1 and 1.8 ± 1.5 mm, respectively, which were smaller than those in the other setups. These displacements were equivalent to those in the previous studies.

Conclusions

Utilizing the masks increased upright setup accuracy in the abdominal setup. The leg immobilization devices and backrest attachments provided the highest setup accuracy in the upright HN setup. These findings will be useful to expand the applicability of upright radiotherapy for various cancer treatments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Patient PositioningRadiotherapy Planning, Computer-AssistedRadiotherapy Setup ErrorsHead and Neck NeoplasmsImmobilizationPostureAbdominal NeoplasmsHumansRadiotherapy DosageRadiotherapy, Intensity-ModulatedMaleAdultFemale

Stichwörter der Autor:innen

inter‐fractionalintra‐fractionalsetup accuracyupright radiotherapy

Autor:innen und Institutionen

  • Department of Accelerator and Medical Physics, Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Radiological Technology Section, Department of Medical Technology, QST Hospital, National Institutes for Quantum Science and Technology, Chiba, Japan.
  • QST Hospital, National Institutes for Quantum Science and Technology, Chiba, Japan.

ORCID-Profile: Yusuke Nomura

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Nomura, Y., Tanaka, S., Takei, H., Maeda, K., Takekoshi, T., Iwakami, H., Takiyama, H., Tajiri, M., Yonai, S., Mizuno, H., Iwata, Y., Inaniwa, T., & Ishikawa, H. (2026). Quantifying upright positioning accuracy with optical surface tracking in radiotherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70527

Vancouver

Nomura Y, Tanaka S, Takei H, Maeda K, Takekoshi T, Iwakami H, et al. Quantifying upright positioning accuracy with optical surface tracking in radiotherapy. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70527

BibTeX
@article{Nomura2026,
  author = {Nomura, Yusuke and Tanaka, Sodai and Takei, Hideyuki and Maeda, Kinji and Takekoshi, Takuro and Iwakami, Hideki and Takiyama, Hirotoshi and Tajiri, Minoru and Yonai, Shunsuke and Mizuno, Hideyuki and Iwata, Yoshiyuki and Inaniwa, Taku and Ishikawa, Hitoshi},
  title = {Quantifying upright positioning accuracy with optical surface tracking in radiotherapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70527}
}
Kostenlos starten →