EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The geometric accuracy of off‐axis targets in stereotactic body radiotherapy treatments across three linear accelerators

Dinesan Chinnaiya, Gopinath Mudhana

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70383 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Dinesan Chinnaiya und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, School of Advanced Sciences, Vellore Institute of Technology, Chennai, India. Hauptthemen laut MEDLINE: Particle Accelerators, Radiosurgery, Radiotherapy Planning, Computer-Assisted, Phantoms, Imaging. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study quantifies isocenter and off‐axis geometric uncertainties using MultiMet Winston–Lutz (WL) tests to optimize gross tumour volume (GTV)‐to‐PTV (planning target volume) margin for single isocenter multiple target (SIMT) stereotactic body radiotherapy (SBRT) across three linear accelerators. Methods and Materials Geometric inaccuracies were quantified for Trilogy (HD‐MLC, 6 MV SRS), TrueBeam (Millennium MLC), and TrueBeam STx (HD‐MLC, 6‐degrees‐of‐freedom (6DoF) couch) using a Sun Nuclear MultiMet‐WL cube containing six tungsten carbide markers arranged along the superior–inferior axis. The electronic portal imaging device (EPID) images acquired at four cardinal gantry angles with varied collimator/couch rotations were analyzed using MultiMet‐WL software (v2.1) to measure 3D (Δ) displacements for all the LINACs. The required GTV‐to‐PTV margins were calculated using a modified van Herk formula (2.5Σ+1.64σ), incorporating measured 3D displacements for isocenter and off‐axis targets.

Results

The TrueBeam STx (HD‐MLC/6DoF) demonstrated superior geometric accuracy, maintaining ≤0.5 mm isocenter precision and ≤0.59 mm off‐axis targeting (3–7 cm). The Trilogy exceeded TG‐142 tolerances (1.06 ± 0.59 to 1.09 ± 0.57 mm) at all targets, requiring 4 mm uniform margins, while the TrueBeam (MMLC) showed optimal variations (isocenter: 0.68 ± 0.34 mm; superior off‐axis: 0.74 ± 0.36 mm). Both TrueBeam platforms achieved sub‐millimeter accuracy but demonstrated direction dependency for off‐axis targets, requiring 2–3 mm anisotropic margins. Notably, isotropic margins introduced up to 11% delineation errors for off‐axis targets due to these machine‐specific geometric variations, highlighting the imperative for platform‐specific margin protocols in SIMT SBRT.

Conclusion

This study demonstrates that routine analysis of MultiMet WL testing is an essential tool for the spatial accuracy of the LINAC to establish machine‐specific PTV margin expansion in SIMT‐SBRT, particularly for targets where rotational errors dominate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Particle AcceleratorsRadiosurgeryRadiotherapy Planning, Computer-AssistedPhantoms, ImagingNeoplasmsHumansRadiotherapy DosageRadiotherapy, Intensity-Modulated

Stichwörter der Autor:innen

SIMT–SBRTWinston–Lutz testgeometric accuracy

Autor:innen und Institutionen

  • Department of Physics, School of Advanced Sciences, Vellore Institute of Technology, Chennai, India.
  • Department of Radiation Oncology, Sri Shankara Cancer Hospital & Research Centre, Bangalore, India.

Zitieren

APA

Chinnaiya, D., & Mudhana, G. (2026). The geometric accuracy of off‐axis targets in stereotactic body radiotherapy treatments across three linear accelerators. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70383

Vancouver

Chinnaiya D, Mudhana G. The geometric accuracy of off‐axis targets in stereotactic body radiotherapy treatments across three linear accelerators. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70383

BibTeX
@article{Chinnaiya2026,
  author = {Chinnaiya, Dinesan and Mudhana, Gopinath},
  title = {The geometric accuracy of off‐axis targets in stereotactic body radiotherapy treatments across three linear accelerators},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70383}
}
Kostenlos starten →