Dosimetric characterization of a Varex VF‐80/μXHP x‐ray unit using open‐ended applicators for superficial radiotherapy

Muhammad Zeeshan iD, Yikai Wu, Zhongyu Qi, Ning Gao, Xi Pei, Xie George Xu

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70326 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Muhammad Zeeshan und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui, China. Hauptthemen laut MEDLINE: Phantoms, Imaging, Radiotherapy Planning, Computer-Assisted, Radiometry, Skin Neoplasms. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Anhui Province Key Research and Development Plan, National Natural Science Foundation of China, Development of Medical Physics and Biomedical Engineering Interdisciplinary Subjects.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Kilovoltage x‐ray units (50–150 kVp) are widely used for skin cancer treatments, necessitating precise dosimetric characterization to ensure accurate dose delivery. This study validates the depth dose data of the VF‐80/𝜇XHP (80 kV, 100 W) x‐ray system for use in low‐kV therapy with a contemporary detector.

Objective

This research aims to characterize the kilovoltage VF‐80/𝜇XHP x‐ray unit with open‐ended PMMA and stainless‐steel applicators of various diameters by utilizing different x‐ray energy values.

Methods

Measurements included machine output reproducibility, applicator leakage and thickness effects, measurement of HVL, reference output dosimetry, and applicator‐to‐phantom spacing. PDD curves were obtained using various filter/kV and applicator combinations with a PTW 34013 parallel‐plate ionization chamber in a solid water phantom and through MC simulations with the TOPAS Monte Carlo code in a water phantom, which were validated against literature data.

Results

The study evaluated around 40 x‐ray beams. The PDDs were measured in a solid water phantom using a PTW 34013 ionization chamber and calculated with the TOPAS Monte Carlo code. Both the measured and computed percent depth dose data were compared to the BJR 25 supplementary. The agreement between ionization chamber measurements and MC calculations with BJR 25 supplementary was within [1.9%, 1.5%] for 50 kV x‐rays and within [0.5%, 0.2%] for 70 kV x‐rays.

Conclusion

This research provides the dosimetric analysis of a kilovoltage VF‐80/μXHP x‐ray machine. The primary focus was on using a PTW 34013 ionization chamber to measure the percentage depth dose in a solid water phantom, along with dose calculations performed using the TOPAS Monte Carlo simulation. The findings align well with existing literature, confirming that this x‐ray unit is suitable for low‐kV x‐ray radiotherapy applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingRadiotherapy Planning, Computer-AssistedRadiometrySkin NeoplasmsParticle AcceleratorsHumansRadiotherapy DosageMonte Carlo MethodRadiotherapy, Intensity-Modulated

Stichwörter der Autor:innen

Monte Carlo simulationsionization chamberlow‐kV radiotherapypercent depth dose

Autor:innen und Institutionen

  • School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui, China.
  • Technology Development Department, Anhui Wisdom Technology Company Limited, Hefei, Anhui, China.
  • Department of Radiation Oncology, The First Affiliated Hospital of the University of Science and Technology of China, Hefei, Anhui, China.

ORCID-Profile: Muhammad Zeeshan

Förderung

  • Anhui Province Key Research and Development Plan
  • National Natural Science Foundation of China
  • Development of Medical Physics and Biomedical Engineering Interdisciplinary Subjects
  • Alliance of National and International Science Organizations for Belt and Road Regions (ANSO)

Zitieren

APA

Zeeshan, M., Wu, Y., Qi, Z., Gao, N., Pei, X., & Xu, X. G. (2025). Dosimetric characterization of a Varex VF‐80/μXHP x‐ray unit using open‐ended applicators for superficial radiotherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70326

Vancouver

Zeeshan M, Wu Y, Qi Z, Gao N, Pei X, Xu XG. Dosimetric characterization of a Varex VF‐80/μXHP x‐ray unit using open‐ended applicators for superficial radiotherapy. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70326

BibTeX
@article{Zeeshan2025,
  author = {Zeeshan, Muhammad and Wu, Yikai and Qi, Zhongyu and Gao, Ning and Pei, Xi and Xu, Xie George},
  title = {Dosimetric characterization of a Varex VF‐80/μXHP x‐ray unit using open‐ended applicators for superficial radiotherapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70326}
}
Kostenlos starten →