Human visual perception‐based grayscale contrast enhancement with adaptive window settings in computed tomography images

Wei Zhou iD, Yi Tian

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70212 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Wei Zhou und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computed Tomography (CT) Concept, Siemens Shanghai Medical Equipment Ltd., Shanghai, China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Phantoms, Imaging, Visual Perception, Image Processing, Computer-Assisted. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Grayscale contrast plays a significant role in medical imaging. This is due to the fact that visual examination, where images are represented with different gray shades on display devices, is essential in current medical applications.

Purpose

The effective contrast enhancement should have the ability to provide sufficient grayscale contrast and natural image appearance in line with human visual perception (HVP). To achieve the goal, the paper proposes a novel method for grayscale contrast improvement in computed tomography (CT) diagnostics.

Methods

A new quantitative physical metric incorporating certain human visual characteristics, termed as contrast‐perceived to spatial frequency ratio (CPSFR), is presented to assess the perceptual quality of grayscale‐based images. The window settings achieved by maximizing CPSFR, Window Settings Automatic , was evaluated and compared with Window Settings Preset and Window Settings Manual both of which are most used in CT diagnostics in terms of target detectability and diagnostic satisfaction. Experiments were carried out with 720 phantom images and 80 patient images. In phantom study, images were acquired with the routine body protocol at varying dose levels and assessed by four CT physicists for identifying signal‐present or signal‐absent. In clinical study, images with liver lesions were evaluated and rated by three radiologists with a 4‐point diagnostic quality score.

Results

The phantom study indicated a statistically significant improvement with Window Settings Automatic , as compared to Window Settings Preset and Window Settings Manual (all p < 0.01) in accuracy and sensitivity for consensus readings. And the clinical study demonstrated Window Settings Automatic had the distinct advantage over other candidates (highest mean score 3.0; > 40% of all top‐scoring votes).

Conclusions

The proposed method is capable of enhancing grayscale contrast in the region that really interests observers and yielding natural image appearance well suited to human visual perception to improve target detectability and diagnostic performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedPhantoms, ImagingVisual PerceptionImage Processing, Computer-AssistedLiver NeoplasmsRadiographic Image Interpretation, Computer-AssistedHumansAlgorithms

Stichwörter der Autor:innen

CT image qualitydisplay windowinggrayscale contrast enhancementhuman visual perception

Autor:innen und Institutionen

  • Department of Computed Tomography (CT) Concept, Siemens Shanghai Medical Equipment Ltd., Shanghai, China.

ORCID-Profile: Wei Zhou

Zitieren

APA

Zhou, W., & Tian, Y. (2025). Human visual perception‐based grayscale contrast enhancement with adaptive window settings in computed tomography images. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70212

Vancouver

Zhou W, Tian Y. Human visual perception‐based grayscale contrast enhancement with adaptive window settings in computed tomography images. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70212

BibTeX
@article{Zhou2025,
  author = {Zhou, Wei and Tian, Yi},
  title = {Human visual perception‐based grayscale contrast enhancement with adaptive window settings in computed tomography images},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70212}
}
Kostenlos starten →