EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantitative beam optimization for radiotherapy of peripheral lung lesions: A pilot study in stereotactic body radiotherapy

Hamed Hooshangnejad, Jina Lee, Leslie Bell, Russell K Hales, Khinh Ranh Voong, Sarah Han-Oh, Kai Ding iD, Reza Farjam

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70029 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Hamed Hooshangnejad und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Radiosurgery, Radiotherapy Planning, Computer-Assisted, Lung Neoplasms, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To quantify beam optimization for stereotactic body radiotherapy (SBRT) of peripheral lung lesions.

Method

The new beam optimization approach was based on maximizing the therapeutic gain (TG) of the beam set by minimizing the average physical depth of the lesion with respect to the beam's eye view (BEV). The new approach was evaluated by replanning the 25 SBRT lesions retrospectively to assess if a better plan is achievable in all aspects. Difference in 25 Gy isodose line volume (IDLV 25 Gy ), IDLV 20 Gy , IDLV 15 Gy , IDLV 10 Gy , and IDLV 5 Gy between the two plan cohorts were calculated as a measure of plan size and fitted in a linear regression model against the changes in the lesion depth with respect to the BEV to assess the relationship between the changes in the treatment depth and that of the plan size.

Results

Beam optimization achieved a better plan in all cases by lowering the depth of treatment with an average of % 20.03 ± 12.30 (3.66%–45.78%). As the depth of treatment decreases, the size of the plan also decreases. We observed a reduction of % 4.64 ± 4.55 (0.02%–21.58%, p < 3.8 × 10 −5 ), %5.16 ± 5.54 (0.03%‐24.68%, p < 0.005), %6.46 ± 6.95 (−1.35%‐29.05%, p < 0.009), %12.83 ± 9.06 (0.89%–37.65%, p < 0.0001), and %14.01 ± 9.87 (1.43%–41.84%, p < 4.5 × 10 −6 ) in IDLV 25 Gy , IDLV 20 Gy , IDLV 15 Gy , IDLV 10 Gy , and IDLV 5 Gy , respectively.

Conclusion

Physical depth of the lesion with respect to the BEV is inversely proportional to the TG of a beam‐set and can be used as a robust and standard metric to select an appropriate beam‐set for SBRT of the peripheral lung lesions. Further evaluation warrants the utility of such concept in routine clinical use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryRadiotherapy Planning, Computer-AssistedLung NeoplasmsRadiotherapy, Intensity-ModulatedHumansRadiotherapy DosageRetrospective StudiesPilot ProjectsOrgans at RiskAlgorithms

Stichwörter der Autor:innen

SBRTbeam optimizationintegral dosetherapeutic gain

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA.
  • Carnegie Center for Surgical Innovation, Johns Hopkins University, Baltimore, Maryland, USA.
  • Department of Radiation Oncology and Molecular Sciences, Johns Hopkins University, Baltimore, Maryland, USA.

ORCID-Profile: Kai Ding

Zitieren

APA

Hooshangnejad, H., Lee, J., Bell, L., Hales, R. K., Voong, K. R., Han-Oh, S., Ding, K., & Farjam, R. (2025). Quantitative beam optimization for radiotherapy of peripheral lung lesions: A pilot study in stereotactic body radiotherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70029

Vancouver

Hooshangnejad H, Lee J, Bell L, Hales RK, Voong KR, Han-Oh S, et al. Quantitative beam optimization for radiotherapy of peripheral lung lesions: A pilot study in stereotactic body radiotherapy. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70029

BibTeX
@article{Hooshangnejad2025,
  author = {Hooshangnejad, Hamed and Lee, Jina and Bell, Leslie and Hales, Russell K and Voong, Khinh Ranh and Han-Oh, Sarah and Ding, Kai and Farjam, Reza},
  title = {Quantitative beam optimization for radiotherapy of peripheral lung lesions: A pilot study in stereotactic body radiotherapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70029}
}
Kostenlos starten →