Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Janatul Madinah Wahabi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Imaging, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Radiotherapy Dosage, Radiotherapy, Intensity-Modulated, Feasibility Studies, Phantoms, Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Higher Education Fundamental Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Radiation dose measurement is an essential part of radiotherapy to verify the correct delivery of doses to patients and ensure patient safety. Recent advancements in radiotherapy technology have highlighted the need for fast and precise dosimeters. Technologies like FLASH radiotherapy and magnetic‐resonance linear accelerators (MR‐LINAC) demand dosimeters that can meet their unique requirements. One promising solution is the plastic scintillator‐based dosimeter with high spatial resolution and real‐time dose output. This study explores the feasibility of using the LuSy dosimeter, an in‐house developed plastic scintillator dosimeter for dose verification across various radiotherapy techniques, including conformal radiotherapy (CRT), intensity‐modulated radiation therapy (IMRT), volumetric‐modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). Materials and methods A new dosimetry system, comprising a new plastic scintillator as the sensing material, was developed and characterized for radiotherapy beams. Treatment plans were created for conformal radiotherapy, IMRT, VMAT, and SRS and delivered to a phantom. LuSy dosimeter was used to measure the delivered dose for each plan on the surface of the phantom and inside the target volumes. Then, LuSy measurements were compared against an ionization chamber, MOSFET dosimeter, radiochromic films, and dose calculated using the treatment planning system (TPS).

Results

For CRT, surface dose measurement by LuSy dosimeter showed a deviation of ‐5.5% and ‐5.4% for breast and abdomen treatment from the TPS, respectively. When measuring inside the target volume for IMRT, VMAT, and SRS, the LuSy dosimeter produced a mean deviation of ‐3.0% from the TPS. Surface dose measurement resulted in higher TPS discrepancies where the deviations for IMRT, VMAT, and SRS were ‐2.0%, ‐19.5%, and 16.1%, respectively.

Conclusion

The LuSy dosimeter was feasible for measuring radiotherapy doses for various treatment techniques. Treatment delivery verification enables early error detection, allowing for safe treatment delivery for radiotherapy patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy DosageRadiotherapy, Intensity-ModulatedFeasibility StudiesPhantoms, ImagingRadiotherapy Planning, Computer-AssistedParticle AcceleratorsHumansRadiosurgeryRadiation DosimetersRadiotherapy, ConformalRadiometryOrgans at RiskNeoplasms

Stichwörter der Autor:innen

IMRTSRSVMATconformal radiotherapyplastic scintillator

Autor:innen und Institutionen

  • Department of Biomedical Imaging, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Radiotherapy and Oncology Department, National Cancer Institute, Putrajaya, Malaysia.
  • Universiti Malaya Research Imaging Centre (UMRIC), Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Flexilicate Sdn. Bhd. Universiti Malaya, Kuala Lumpur, Malaysia.
  • Clinical Oncology Unit, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.

ORCID-Profile: Janatul Madinah Wahabi, Jeannie Hsiu Ding Wong

Förderung

  • Ministry of Higher Education Fundamental Research

Zitieren

APA

Wahabi, J. M., Wong, J. H. D., Mahdiraji, G. A., & Ung, N. M. (2024). Feasibility of determining external beam radiotherapy dose using LuSy dosimeter. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14387

Vancouver

Wahabi JM, Wong JHD, Mahdiraji GA, Ung NM. Feasibility of determining external beam radiotherapy dose using LuSy dosimeter. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14387

BibTeX
@article{Wahabi2024,
  author = {Wahabi, Janatul Madinah and Wong, Jeannie Hsiu Ding and Mahdiraji, Ghafour A and Ung, Ngie Min},
  title = {Feasibility of determining external beam radiotherapy dose using LuSy dosimeter},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14387}
}
Kostenlos starten →