EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Film measurement and analytical approach for assessing treatment accuracy and latency in a magnetic resonance‐guided radiotherapy system

Hiroki Nakayama iD, Hiroyuki Okamoto, Satoshi Nakamura, Kotaro Iijima iD, Takahito Chiba, Mihiro Takemori, Tetsu Nakaichi iD, Shohei Mikasa, Kyohei Fujii, Tatsuya Sakasai, Junichi Kuwahara, Yuki Miura und 5 weitere

Journal of Applied Clinical Medical Physics · 2023

DOI: 10.1002/acm2.13915 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2023. Verfasst von Hiroki Nakayama und 16 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Chuo-ku, Tokyo, Japan. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Grant-in-Aid for Young Scientists, National Cancer Center Research and Development Fund, AMED.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

We measure the dose distribution of gated delivery for different target motions and estimate the gating latency in a magnetic resonance‐guided radiotherapy (MRgRT) system.

Method

The dose distribution accuracy of the gated MRgRT system (MRIdian, Viewray) was investigated using an in‐house‐developed phantom that was compatible with the magnetic field and gating method. This phantom contains a simulated tumor and a radiochromic film (EBT3, Ashland, Inc.). To investigate the effect of the number of beam switching and target velocity on the dose distribution, two types of target motions were applied. One is that the target was periodically moved at a constant velocity of 5 mm/s with different pause times (0, 1, 3, 10, and 20 s) between the motions. During different pause times, different numbers of beams were switched on/off. The other one is that the target was moved at velocities of 3, 5, 8, and 10 mm/s without any pause (i.e., continuous motion). The gated method was applied to these motions at MRIdian, and the dose distributions in each condition were measured using films. To investigate the relation between target motion and dose distribution in the gating method, we compared the results of the gamma analysis of the calculated and measured dose distributions. Moreover, we analytically estimated the gating latencies from the dose distributions measured using films and the gamma analysis results.

Results

The gamma pass rate linearly decreased with increasing beam switching and target velocity. The overall gating latencies of beam‐hold and beam‐on were 0.51 ± 0.17 and 0.35 ± 0.05 s, respectively.

Conclusions

Film measurements highlighted the factors affecting the treatment accuracy of the gated MRgRT system. Our analytical approach, employing gamma analysis on films, can be used to estimate the overall latency of the gated MRgRT system.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedHumansMotionMagnetic Resonance SpectroscopyRadiotherapy DosagePhantoms, Imaging

Stichwörter der Autor:innen

gating methodlatencymagnetic resonance-guided radiotherapyquality assurance

Autor:innen und Institutionen

  • Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Chuo-ku, Tokyo, Japan.
  • Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Higashioku, Arakawa-ku, Tokyo, Japan.
  • Department of Radiation Sciences, Komazawa University, Setagaya-ku, Tokyo, Japan.
  • Department of Radiological Technology, National Cancer Center Hospital, Chuo-ku, Tokyo, Japan.
  • Department of Radiological Technology, National Cancer Center Hospital East, Kashiwa, Chiba, Japan.
  • Department of Radiation Oncology, National Cancer Center Hospital, Chuo-ku, Tokyo, Japan.

ORCID-Profile: Hiroki Nakayama, Kotaro Iijima, Tetsu Nakaichi

Förderung

  • Grant-in-Aid for Young Scientists
  • National Cancer Center Research and Development Fund
  • AMED
  • Japan Agency for Medical Research and Development

Zitieren

APA

Nakayama, H., Okamoto, H., Nakamura, S., Iijima, K., Chiba, T., Takemori, M., Nakaichi, T., Mikasa, S., Fujii, K., Sakasai, T., Kuwahara, J., Miura, Y., Fujiyama, D., Tsunoda, Y., Hanzawa, T., Igaki, H., & Chang, W. (2023). Film measurement and analytical approach for assessing treatment accuracy and latency in a magnetic resonance‐guided radiotherapy system. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.13915

Vancouver

Nakayama H, Okamoto H, Nakamura S, Iijima K, Chiba T, Takemori M, et al. Film measurement and analytical approach for assessing treatment accuracy and latency in a magnetic resonance‐guided radiotherapy system. Journal of Applied Clinical Medical Physics. 2023. doi:10.1002/acm2.13915

BibTeX
@article{Nakayama2023,
  author = {Nakayama, Hiroki and Okamoto, Hiroyuki and Nakamura, Satoshi and Iijima, Kotaro and Chiba, Takahito and Takemori, Mihiro and Nakaichi, Tetsu and Mikasa, Shohei and Fujii, Kyohei and Sakasai, Tatsuya and Kuwahara, Junichi and Miura, Yuki and Fujiyama, Daisuke and Tsunoda, Yuki and Hanzawa, Takuma and Igaki, Hiroshi and Chang, Weishan},
  title = {Film measurement and analytical approach for assessing treatment accuracy and latency in a magnetic resonance‐guided radiotherapy system},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2023},
  doi = {10.1002/acm2.13915}
}
Kostenlos starten →