A retrospective study of automatic progressive optimization for lung cancer radiotherapy plans on the Halcyon and RayStation systems
PeerJ · 2025
DOI: 10.7717/peerj.19831 ↗Kurz gefasst
Fachartikel in der Zeitschrift PeerJ, 2025. Verfasst von Kainan Shao und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Zhejiang Provincial People's Hospital, Hangzhou, Zhejiang, China. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Lung Neoplasms, Carcinoma, Non-Small-Cell Lung. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zhejiang Province Natural Science Foundation of China, Medical and Health Research Project of Zhejiang Province, Zhejiang Provincial Basic Public Welfare Research Project.
Abstract (Originalsprache)
This study aims to evaluate the feasibility of using RayStation’s scripting function to generate automated radiotherapy plans for non-small cell lung cancer (NSCLC) patients on a Varian Halcyon accelerator and to compare their dosimetric characteristics with those of retrospectively collected manual clinical plans. A total of 63 conventional fractionation plans for NSCLC, previously designed using RayStation 4.5 for a variety of linear accelerators—including Trilogy, TrueBeam, Halcyon, and Elekta Infinity—were compared with automated plans generated using RayStation 9.0 for Halcyon. This heterogeneous control group was chosen to reflect real-world clinical practice across multiple platforms. Target coverage, doses to organs at risk (OARs), monitor units, and plan complexity were assessed. The automated plans showed improved dose conformity and lower OAR exposure under the planning configuration used. However, these differences should be interpreted with caution, as the comparison involved different treatment planning systems (TPS) versions and hardware platforms. Further controlled studies using the same TPS and linac are needed to validate the observed improvements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Zhejiang Provincial People's Hospital, Hangzhou, Zhejiang, China.
- Department of Radiation Physics, Zhejiang Cancer Hospital, Hangzhou, Zhejiang, China.
Förderung
- Zhejiang Province Natural Science Foundation of China
- Medical and Health Research Project of Zhejiang Province
- Zhejiang Provincial Basic Public Welfare Research Project
Zitieren
APA
Shao, K., Du, F., Qiu, L., Zhang, Y., Li, Y., Ding, J., Zhan, W., & Chen, W. (2025). A retrospective study of automatic progressive optimization for lung cancer radiotherapy plans on the Halcyon and RayStation systems. PeerJ. https://doi.org/10.7717/peerj.19831
Vancouver
Shao K, Du F, Qiu L, Zhang Y, Li Y, Ding J, et al. A retrospective study of automatic progressive optimization for lung cancer radiotherapy plans on the Halcyon and RayStation systems. PeerJ. 2025. doi:10.7717/peerj.19831
BibTeX
@article{Shao2025,
author = {Shao, Kainan and Du, Fenglei and Qiu, Lingyun and Zhang, Yinghao and Li, Yucheng and Ding, Jieni and Zhan, Wenming and Chen, Weijun},
title = {A retrospective study of automatic progressive optimization for lung cancer radiotherapy plans on the Halcyon and RayStation systems},
journal = {PeerJ},
year = {2025},
doi = {10.7717/peerj.19831}
}
EUVIMED