Beam orientation optimization in IMRT using sparse mixed integer programming and non-convex fluence map optimization
Physics in Medicine & Biology · 2025
DOI: 10.1088/1361-6560/ade8ce ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2025. Verfasst von Yang Lei und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Icahn School of Medicine at Mount Sinai, New York, NY, United States of America. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Abstract (Originalsprache)
Objective. Beam orientation optimization (BOO) in intensity-modulated radiation therapy (IMRT) is a complex, non-convex problem traditionally addressed with heuristic methods. Approach. This work demonstrates the potential improvement of the proposed BOO, providing a mathematically grounded benchmark that can guide and validate heuristic BOO methods, while also offering a computationally efficient workflow suitable for clinical application. A novel framework integrating second-order cone programming (SOCP) relaxation, sparse mixed integer programming (SMIP), and deep inverse optimization is proposed. Nonconvex dose-volume constraints were managed via SOCP relaxation, ensuring convexity while maintaining sparsity. BOO was formulated as an SMIP problem with binary beam selection, solved using an augmented Lagrange method. To accelerate optimization, a neural network approximated optimal solution, improving computational efficiency eightfold. A retrospective analysis of 12 locally advanced non-small cell lung cancer (NSCLC) patients (60 Gy prescription) compared automated BOO-selected beam angles with expert selections, evaluating dosimetric metrics such as planning target volume (PTV) maximum dose, D98%, lung V20, and mean heart and esophagus dose. Main results. In 12 retrospective study, the automated BOO demonstrated superior dose conformity and sparing of critical structures. Specifically, the BOO plans achieved comparable PTV coverage (maximum: 61.7 ± 1.4 Gy vs. 62.1 ± 1.5 Gy, D98%: 59.5 ± 0.7 Gy vs. 59.5 ± 0.6 Gy, D2%: 61.2 ± 1.3 Gy vs. 61.4 ± 1.4 Gy with p -values >0.5) but demonstrated improved sparing for lungs (V20: 9.8 ± 2.2% vs. 11.5 ± 2.3%, p -value: 0.01), heart (mean: 3.3 ± 0.6 Gy vs. 4.3 ± 0.5 Gy, p -value: 0.04), esophagus (mean: 0.5 ± 1.3 Gy vs. 1.8 ± 1.5 Gy, p -value: 0.02), and spinal cord (max: 7.2 ± 3.4 Gy vs. 9.0 ± 3.2 Gy, p -value < 0.01) compared to human-selected plans. Significance. This approach highlighted the potential of BOO to enhance treatment efficacy by optimizing beam angles more effectively than manual selection. This framework establishes a benchmark for BOO in IMRT, enhancing heuristic methods through a hybrid framework that combines mathematical optimization with targeted heuristics to improve solution quality and computational efficiency. The integration of SMIP and deep inverse optimization significantly improves computational efficiency and plan quality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Icahn School of Medicine at Mount Sinai, New York, NY, United States of America.
- New York Proton Center, New York, NY, United States of America.
- Department of Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, United States of America.
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America.
Zitieren
APA
Lei, Y., Zhang, J., Yang, K., Wei, S., Liu, R., Fu, Y., Lei, Y., Lin, H., Simone, C. B., Rosenzweig, K., & Liu, T. (2025). Beam orientation optimization in IMRT using sparse mixed integer programming and non-convex fluence map optimization. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ade8ce
Vancouver
Lei Y, Zhang J, Yang K, Wei S, Liu R, Fu Y, et al. Beam orientation optimization in IMRT using sparse mixed integer programming and non-convex fluence map optimization. Physics in Medicine & Biology. 2025. doi:10.1088/1361-6560/ade8ce
BibTeX
@article{Lei2025,
author = {Lei, Yang and Zhang, Jiahan and Yang, Kaida and Wei, Shouyi and Liu, Ruirui and Fu, Yabo and Lei, Yu and Lin, Haibo and Simone, Charles B and Rosenzweig, Kenneth and Liu, Tian},
title = {Beam orientation optimization in IMRT using sparse mixed integer programming and non-convex fluence map optimization},
journal = {Physics in Medicine & Biology},
year = {2025},
doi = {10.1088/1361-6560/ade8ce}
}
EUVIMED