Internal and marginal fit of digitally fabricated all-ceramic crowns with auxiliary retentive features on short clinical abutments: a micro-CT study
PeerJ · 25.08.2025 · 13 · e19813
DOI: 10.7717/peerj.19813 ↗Kurz gefasst
Fachartikel in der Zeitschrift PeerJ, online erschienen am 25.08.2025. Verfasst von Saeed M Alqahtani und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Aseer, Saudi Arabia. Hauptthemen laut MEDLINE: Crowns, Computer-Aided Design, Ceramics, Dental Prosthesis Design. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 84 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deanship of Research and Graduate Studies at King Khalid University through Small Research Project.
Abstract (Originalsprache)
Background
Short clinical crowns/abutments (SCC) pose a challenge in achieving adequate retention. Auxiliary retentive features (ARF), such as grooves, are commonly employed to enhance retention. The marginal gap (MG) and internal fit (IF) of restorations are critical factors influencing clinical success. This study aimed to evaluate the MG, IF, and cement volume of digitally fabricated (computer-aided design (CAD) and computer-aided manufacturing (CAM)) all-ceramic crowns with and without grooves on SCC using micro-computed tomography (micro-CT).
Methods
A mandibular second molar typodont tooth was prepared to simulate SCC. Four groups of crowns ( n = 30 per group) were fabricated: Group 1: CAD/CAM zirconia without grooves, Group 2: CAD/CAM zirconia with grooves, Group 3: CAD/CAM lithium disilicate with grooves, Group 4: Conventional lithium disilicate with grooves. Crowns were cemented using resin cement. MG, IF, and cement volume were evaluated using micro-CT. Gap measurements were taken in two planes across seven zones (Z1 to Z7). Statistical analysis was performed using one-way ANOVA and post hoc Tukey tests.
Results
Significant differences in MG and IF were observed among the groups ( p < 0.001). Group 1 exhibited the lowest MG and IF, followed by Group 3, Group 2, and Group 4. Group 4 showed the highest average marginal discrepancy (AMD) and average wall discrepancy (AWD) ((AMD: Z1 = 197.36 ± 10.56 µm; Z7 = 226.5 ± 8.24 µm), (AWD: Z2 = 150.05 ± 10.89 µm; Z6 = 169.38 ± 10.57 µm)), followed by Group 2 > Group 3 > Group 1. The greatest discrepancy at the cuspal area was observed in Group 2, followed by Group 3 > Group 1 > Group 4. In the central fossa, the maximum discrepancy was also noted in Group 2 (CFD = 194.48 ± 13.71 µm). No significant differences were found in total cement space volume among the groups.
Conclusion
CAD/CAM crowns with grooves demonstrated clinically acceptable MG and IF values, with lithium disilicate crowns showing superior performance. These findings support the use of CAD/CAM technology for SCC restorations and underscore the importance of material selection and crown design for optimal clinical outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Aseer, Saudi Arabia.
- Department of Dental Research Cell, Dr. D. Y. Patil Dental College and Hospital, Pune, Maharashtra, India.
- Department of Prosthetic Dentistry, SPDC, DMIHER (DU), Wardha, Maharashtra, India.
- Department of Restorative Dental Science, College of Dentistry, King Khalid University, Abha, Aseer, Saudi Arabia.
- Department of Prosthodontic, Hamad Dental Hospital, Ministry of Health, Doha, Qatar.
Förderung
- Deanship of Research and Graduate Studies at King Khalid University through Small Research Project
Zitieren
APA
Alqahtani, S. M., Chaturvedi, S., Addas, M. K., Alqahtani, N. M., Zarbah, M. A., Al Wadei, M. H. D., Alsaeed, F. A., AlJaadan, Y. S., Alqahtani, A. A. A., Al Mansooi, M. A., & Chaturvedi, M. (2025). Internal and marginal fit of digitally fabricated all-ceramic crowns with auxiliary retentive features on short clinical abutments: a micro-CT study. PeerJ, 13, e19813. https://doi.org/10.7717/peerj.19813
Vancouver
Alqahtani SM, Chaturvedi S, Addas MK, Alqahtani NM, Zarbah MA, Al Wadei MHD, et al. Internal and marginal fit of digitally fabricated all-ceramic crowns with auxiliary retentive features on short clinical abutments: a micro-CT study. PeerJ. 2025;13:e19813. doi:10.7717/peerj.19813
BibTeX
@article{Alqahtani2025,
author = {Alqahtani, Saeed M and Chaturvedi, Saurabh and Addas, Mohamed Khaled and Alqahtani, Nasser M and Zarbah, Mohammad A and Al Wadei, Mohammed Hussain Dafer and Alsaeed, Feras Ali and AlJaadan, Yasir Saad and Alqahtani, Ali Abdullah Ali and Al Mansooi, Mohammed Abdullah and Chaturvedi, Mudita},
title = {Internal and marginal fit of digitally fabricated all-ceramic crowns with auxiliary retentive features on short clinical abutments: a micro-CT study},
journal = {PeerJ},
year = {2025},
volume = {13},
pages = {e19813},
doi = {10.7717/peerj.19813}
}
EUVIMED