EUVIMEDEUVIMED entdecken
Crossref

Fracture resistance of hybrid ceramic abutments with different restoration lengths: A pilot study

Rani D'haese iD, Valentin Vervack, Manon Tytgat, Stefan Vandeweghe

Clinical Implant Dentistry and Related Research · 2024

DOI: 10.1111/cid.13322 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, 2024. Verfasst von Rani D'haese und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Reconstructive Dentistry, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium. Hauptthemen laut MEDLINE: Dental Abutments, Zirconium, Titanium, Dental Stress Analysis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

In this pilot study, the fracture resistance of hybrid abutments with different restoration lengths was investigated. Materials and Methods Sixteen monolithic zirconia restorations of an upper right incisor were designed to fit a titanium base abutment. Eight central incisors had a crown length of 8 mm (T1) and the other half a length of 12 mm (T2). All crowns were cemented on the titanium base using a resin cement. After cementation, the samples were placed in a thermocycler for 5000 cycles. Fracture strength was measured using a universal test machine. Deformations and fractures of the samples were investigated.

Results

The mean fracture resistance of T1 was 515 N (SD 96 N, 339–650) and 305 N (SD 57 N, 234–408) for T2 ( p < 0.001). Both groups showed deformation of the titanium base, with no significant difference between both groups ( p = 0.200). A difference in fracture type ( p = 0.013) was observed, with significantly more screw fractures occurring in group T1 ( p = 0.026).

Conclusion

Within the limitations of this study, hybrid restorations with standard titanium base abutments can withstand forces that have been associated with chewing, irrespective of the crown length. However, the shorter crowns demonstrated more fatal fractures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental AbutmentsZirconiumTitaniumDental Stress AnalysisDental Restoration FailurePilot ProjectsHumansCrownsCeramicsResin CementsDental Prosthesis Design

Stichwörter der Autor:innen

hybrid abutmenttitanium base

Substanzen

ZirconiumTitaniumzirconium oxideResin Cements

Autor:innen und Institutionen

  • Department of Reconstructive Dentistry, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.
  • Department of Periodontology, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.

ORCID-Profile: Rani D'haese

Zitieren

APA

D'haese, R., Vervack, V., Tytgat, M., & Vandeweghe, S. (2024). Fracture resistance of hybrid ceramic abutments with different restoration lengths: A pilot study. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.13322

Vancouver

D'haese R, Vervack V, Tytgat M, Vandeweghe S. Fracture resistance of hybrid ceramic abutments with different restoration lengths: A pilot study. Clinical Implant Dentistry and Related Research. 2024. doi:10.1111/cid.13322

BibTeX
@article{Dhaese2024,
  author = {D'haese, Rani and Vervack, Valentin and Tytgat, Manon and Vandeweghe, Stefan},
  title = {Fracture resistance of hybrid ceramic abutments with different restoration lengths: A pilot study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2024},
  doi = {10.1111/cid.13322}
}
Kostenlos starten →