EUVIMEDEUVIMED entdecken
Crossref

Toward Faster and Lower-Cost Prosthetic Socket Fabrication: Mechanical Coupon-Level Testing of FDM-Printed PLA/PETG Versus Lamination

Hussein Dhameer Hussein, Wajdi Sadik Aboud

AUIQ Technical Engineering Science · 04.05.2026 · 3 (2)

DOI: 10.70645/3078-3437.1062 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AUIQ Technical Engineering Science, online erschienen am 04.05.2026. Verfasst von Hussein Dhameer Hussein und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Additive manufacturing is increasingly being adopted in prosthetic manufacturing because digital workflows can reduce production time and improve repeatability compared to traditional lamination. This study measured two FDM polymers—polylactic acid (PLA) and polyethylene terephthalate glycol (PETG)—against a baseline of Perlon epoxy laminate (not including carbon reinforcement) using standardized coupon tests (n = 3 per test). PLA and PETG samples were printed at 100% fill with a 0.6 mm nozzle, while laminate coupons were prepared by wet layup and cut to the required geometry. Tensile testing followed ASTM D638 and three-point bending followed ASTM D790, modulus, 0.2% offset yield strength, and ultimate strength were derived from stress-strain curves. In tension, PETG showed higher UTS (38.71 ± 1.97 MPa), while PLA showed a slightly higher modulus (0.363 ± 0.104 GPa); The laminate showed lower tensile strength (28.33 ± 2.29 MPa). In bending, PETG achieved the highest bending strength (70.62 ± 3.15 MPa), while PLA showed higher bending stiffness (Ef = 2.07 ± 0.12 GPa) than PETG (1.72 ± 0.02 GPa). To strengthen the technical relevance, a simplified linear elastic finite element model of a three-point bending configuration was demonstrated, confirming the expected midpoint stress concentration and material-dependent deflection. Overall, the findings support evidence-based material screening for prosthetic socket construction, while socket-level validation under standardized structural loading is still needed.

Zitieren

APA

Hussein, H. D., & Aboud, W. S. (2026). Toward Faster and Lower-Cost Prosthetic Socket Fabrication: Mechanical Coupon-Level Testing of FDM-Printed PLA/PETG Versus Lamination. AUIQ Technical Engineering Science, 3(2). https://doi.org/10.70645/3078-3437.1062

Vancouver

Hussein HD, Aboud WS. Toward Faster and Lower-Cost Prosthetic Socket Fabrication: Mechanical Coupon-Level Testing of FDM-Printed PLA/PETG Versus Lamination. AUIQ Technical Engineering Science. 2026;3(2). doi:10.70645/3078-3437.1062

BibTeX
@article{Hussein2026,
  author = {Hussein, Hussein Dhameer and Aboud, Wajdi Sadik},
  title = {Toward Faster and Lower-Cost Prosthetic Socket Fabrication: Mechanical Coupon-Level Testing of FDM-Printed PLA/PETG Versus Lamination},
  journal = {AUIQ Technical Engineering Science},
  year = {2026},
  volume = {3},
  number = {2},
  doi = {10.70645/3078-3437.1062}
}
Kostenlos starten →