EUVIMEDEUVIMED entdecken
Crossref

Round versus Locator Attachment Effect on The Retention Forces of Implant-Supported Maxillary Overdentures. A Comparative In Vitro Study

Esmail Albakoush, Ashraf Attia, Ahmed Zahmoul, Abd Aldayim Qidarah

Razi Medical Journal · 30.08.2026

DOI: 10.69667/rmj.26309 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Razi Medical Journal, online erschienen am 01.08.2026. Verfasst von Esmail Albakoush und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to evaluate and compare the effect of round bar versus locator attachments on the retention of an implant-supported maxillary overdenture. An acrylic resin model of an edentulous maxilla without alveolar undercut was fabricated, and four laboratory implant analogs were inserted in the canine and second premolar areas. Mucosal simulation was prepared over the model. The implants were attached by bar attachment. According to the types of bar attachment were classified into two groups: Group I: Round bar attachment (Control group). Group II: Locator attachment. (Test group). Maxillary experimental overdentures were made. The UTM was used to measure dislodging forces at the beginning of the study (initial retention) and after 540 cycles of denture insertion and removal (final retention). Then the statistical analysis was performed. The initial and final retention forces after repeated insertions and removals for vertical dislodging force. Rounded bar recorded the higher retentive force than the Locator attachment. Conclusion: Rounded bar recorded significantly higher retentive forces compared to Locator attachment.

Zitieren

APA

Albakoush, E., Attia, A., Zahmoul, A., & Qidarah, A. A. (2026). Round versus Locator Attachment Effect on The Retention Forces of Implant-Supported Maxillary Overdentures. A Comparative In Vitro Study. Razi Medical Journal. https://doi.org/10.69667/rmj.26309

Vancouver

Albakoush E, Attia A, Zahmoul A, Qidarah AA. Round versus Locator Attachment Effect on The Retention Forces of Implant-Supported Maxillary Overdentures. A Comparative In Vitro Study. Razi Medical Journal. 2026. doi:10.69667/rmj.26309

BibTeX
@article{Albakoush2026,
  author = {Albakoush, Esmail and Attia, Ashraf and Zahmoul, Ahmed and Qidarah, Abd Aldayim},
  title = {Round versus Locator Attachment Effect on The Retention Forces of Implant-Supported Maxillary Overdentures. A Comparative In Vitro Study},
  journal = {Razi Medical Journal},
  year = {2026},
  doi = {10.69667/rmj.26309}
}
Kostenlos starten →