Comparative Analysis of Retention in Different Attachment Systems for Implant-Supported Overdentures
Journal of Pharmacy and Bioallied Sciences · 2025-06 · 17 (Suppl 2) · S1374-S1376
DOI: 10.4103/jpbs.jpbs_1682_24 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Pharmacy and Bioallied Sciences, online erschienen am 18.06.2025. Verfasst von Ali Alenezi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, Saudi Arabia. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
A BSTRACT Background: Implant-retained overdentures have become a popular choice in prosthodontics, providing enhanced stability and comfort for edentulous patients. The retention and stability of these overdentures largely depend on the attachment system used. A total of 60 edentulous patients requiring mandibular implant-retained overdentures were selected and divided into three groups (n = 20 per group) based on the attachment system: Group A (ball attachments), Group B (bar attachments), and Group C (locator attachments). Each patient received two mandibular implants to support their overdenture. Retention force was measured using a dynamometer at baseline, and follow-up measurements were conducted at 3 months and 6 months. Patient satisfaction was also assessed using a standardized questionnaire focusing on retention, comfort, and overall satisfaction.
Results
At baseline, Group A (ball attachment) showed an average retention force of 8.2 ± 0.4 N, Group B (bar attachment) demonstrated 10.5 ± 0.6 N, and Group C (locator attachment) showed 9.8 ± 0.5 N. After 6 months, retention decreased slightly in all groups, with final values of 7.8 ± 0.5 N in Group A, 10.0 ± 0.4 N in Group B, and 9.5 ± 0.3 N in Group C. Patient satisfaction scores were highest in Group B (bar attachment) with an average score of 8.9/10, followed by Group C (locator attachment) with 8.5/10, and Group A (ball attachment) with 7.8/10. Statistical analysis showed a significant difference in retention and satisfaction between the bar attachment group and the other groups (P < 0.05).
Conclusion
Among the attachment systems studied, the bar attachment provided the highest retention force and patient satisfaction, followed by the locator attachment. The ball attachment, while effective, showed comparatively lower retention and satisfaction scores.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, Saudi Arabia.
- Department of Prosthodontics, Dentistry Program, Batterjee Medical College, Jeddah, Makkah, Saudi Arabia.
- Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
- Division of Prosthodontics, Oral and Maxillofacial Department, College of Dental Medicine, Umm Al-Qura University, Makkah, Saudi Arabia.
- Department of Endodontics, Dental Speciality Center, Althagr General Hospital, Ministry of Health, First Health Cluster, Jeddah, Saudi Arabia.
Zitieren
APA
Alenezi, A., Niyazi, A. A., Munshi, N., Alsaggaf, A. U., Alghalib, T. A., Huraib, W. M., & Alharbi, M. S. (2025). Comparative Analysis of Retention in Different Attachment Systems for Implant-Supported Overdentures. Journal of Pharmacy and Bioallied Sciences, 17(Suppl 2), S1374-S1376. https://doi.org/10.4103/jpbs.jpbs_1682_24
Vancouver
Alenezi A, Niyazi AA, Munshi N, Alsaggaf AU, Alghalib TA, Huraib WM, et al. Comparative Analysis of Retention in Different Attachment Systems for Implant-Supported Overdentures. Journal of Pharmacy and Bioallied Sciences. 2025;17(Suppl 2):S1374-S1376. doi:10.4103/jpbs.jpbs_1682_24
BibTeX
@article{Alenezi2025,
author = {Alenezi, Ali and Niyazi, Adham A and Munshi, Nabeel and Alsaggaf, Arwa U and Alghalib, Thamer A and Huraib, Wayel M and Alharbi, Muhannad S},
title = {Comparative Analysis of Retention in Different Attachment Systems for Implant-Supported Overdentures},
journal = {Journal of Pharmacy and Bioallied Sciences},
year = {2025},
volume = {17},
number = {Suppl 2},
pages = {S1374--S1376},
doi = {10.4103/jpbs.jpbs_1682_24}
}
EUVIMED