INTER-EXAMINER AND INTRA-EXAMINER RELIABILITY OF THE ACTIVATOR LEG-LENGTH ANALYSIS PROCEDURE AMONG EXPERIENCED CLINICIANS
Journal of Contemporary Chiropractic · 02.11.2026 · 9 (1)
DOI: 10.67681/001c.173479 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Contemporary Chiropractic, online erschienen am 02.11.2026. Verfasst von Afsar Sokhansanj und 2 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
To evaluate the inter-examiner and intra-examiner reliability of the Activator leg-length analysis (LLA) procedure among experienced clinicians.
Methods
Twenty-four subjects (12 male, 12 female) were recruited from a chiropractic university population. To maintain a rigorous blinding protocol, subjects wore identical shoes and socks and were positioned behind a curtain. Three clinicians, each with over 10 years of experience and advanced-proficiency ratings in the Activator Method, performed the examinations. Examiners were blindfolded during subject setup to ensure they remained blinded to subject identity. Each clinician evaluated every subject three times in a randomized order (Trials A, B, and C), with subjects unmounting and walking between trials to simulate clinical conditions. Leg-length inequality (LLI) was recorded using both a 5-level categorization (side and magnitude of 1/4 in) and a collapsed 3-level categorization (side only). Reliability was assessed using Kappa statistics (κ) and percentage of agreement.
Results
Inter-examiner reliability for determining the side of LLI was variable, ranging from fair to substantial. The highest agreement occurred between the 2 examiners with shared instructional backgrounds, reaching κ=0.80 (91.7% agreement) by the third trial. However, inter-examiner reliability for detecting specific magnitude (>1/4 in) was lower, peaking at κ=0.34. Intra-examiner reliability across the 3 trials was largely fair to moderate, with Kappa values ranging from κ=0.22 to 0.61. When the 5-level categorization for magnitude was used, reliability for all examiners dropped to the “slight to fair” range.
Conclusion
The Activator LLA procedure demonstrates variable reliability that appears influenced by shared clinical training and the specific categorization of findings. While substantial agreement can be achieved in identifying the side of a short leg, the procedure is not a reliable tool for quantifying the specific magnitude of LLI. These findings suggest that visual LLA should be interpreted with caution and supplemented by objective clinical indicators.
Zitieren
APA
Sokhansanj, A., Wells, R., & Marzban, F. (2026). INTER-EXAMINER AND INTRA-EXAMINER RELIABILITY OF THE ACTIVATOR LEG-LENGTH ANALYSIS PROCEDURE AMONG EXPERIENCED CLINICIANS. Journal of Contemporary Chiropractic, 9(1). https://doi.org/10.67681/001c.173479
Vancouver
Sokhansanj A, Wells R, Marzban F. INTER-EXAMINER AND INTRA-EXAMINER RELIABILITY OF THE ACTIVATOR LEG-LENGTH ANALYSIS PROCEDURE AMONG EXPERIENCED CLINICIANS. Journal of Contemporary Chiropractic. 2026;9(1). doi:10.67681/001c.173479
BibTeX
@article{Sokhansanj2026,
author = {Sokhansanj, Afsar and Wells, Ronald and Marzban, Farshid},
title = {INTER-EXAMINER AND INTRA-EXAMINER RELIABILITY OF THE ACTIVATOR LEG-LENGTH ANALYSIS PROCEDURE AMONG EXPERIENCED CLINICIANS},
journal = {Journal of Contemporary Chiropractic},
year = {2026},
volume = {9},
number = {1},
doi = {10.67681/001c.173479}
}
EUVIMED