Inter- and Intra-Observer Reliability for Colon Capsule CLEansing Assessment and Report
Endoscopy International Open · 30.09.2026 · 14 (CP)
DOI: 10.1055/a-2961-4842 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 30.09.2026. Verfasst von Eimear Gibbons und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of GastroenterologyConnolly Hospital BlanchardstownBlanchardstownDublinIreland. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Royal College of Surgeons in Ireland.
Abstract (Originalsprache)
A validated scoring system for reporting of colonic cleanliness at colon capsule endoscopy (CCE) is not routinely used to date and great inter-observer variability exists. To ensure appropriate and standardised bowel cleansing reporting, a validated scoring system is of great importance. This would improve the quality of colon capsule reporting and facilitate optimisation of bowel preparation protocols by supporting research reliability. A novel system named Colon Capsule CLEansing Assessment and Report (CC-Clear) has shown superior inter- and intra-observer agreement to the Leighton-Rex scale, an earlier scoring system from 2011. This was a retrospective, single-centre study assessing the intra- and inter-observer reliability of CC-Clear. Materials and Methods Studies were identified retrospectively from the capsule database of a tertiary referral centre. In all, 30 consecutive complete CCE were included. Three expert capsule readers reviewed and reported each examination twice. Results and Conclusion The inter-observer agreement was reported as Kendall’s W and was 0.8, p < 0.01. An intra-rater reliability analysis was performed between the first and second readings of the three readers. The weighted Cohen’s Kappa showed that there was moderate agreement between the readings of Reader A with κ = 0.52 and p < 0.001. For Reader B, the weighted Cohen’s Kappa showed moderate agreement between first and second readings, κ = 0.5 and p < 0.001. For Reader C, the weighted Cohen’s Kappa revealed almost perfect agreement between reading with κ = 0.8 and p < 0.001. CC-Clear is a simple tool for the CCE reader to utilise and has been shown again here to have excellent inter- and intra-observer reliability.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of GastroenterologyConnolly Hospital BlanchardstownBlanchardstownDublinIreland.
- Department of Gastroenterology and Clinical MedicineTallaght University HospitalDublinDublinIreland.
- Department of GastroenterologyBeaumont HospitalDublinLeinsterIreland.
Förderung
- Royal College of Surgeons in Ireland
Zitieren
APA
Gibbons, E., Ismail, S., AlSharqi, D., Keating, L., Smyth, C., Farrell, R., Hall, B., & Kelly, O. (2026). Inter- and Intra-Observer Reliability for Colon Capsule CLEansing Assessment and Report. Endoscopy International Open, 14(CP). https://doi.org/10.1055/a-2961-4842
Vancouver
Gibbons E, Ismail S, AlSharqi D, Keating L, Smyth C, Farrell R, et al. Inter- and Intra-Observer Reliability for Colon Capsule CLEansing Assessment and Report. Endoscopy International Open. 2026;14(CP). doi:10.1055/a-2961-4842
BibTeX
@article{Gibbons2026,
author = {Gibbons, Eimear and Ismail, Syafiq and AlSharqi, Dana and Keating, Lisa and Smyth, Claire and Farrell, Richard and Hall, Barry and Kelly, Orlaith},
title = {Inter- and Intra-Observer Reliability for Colon Capsule CLEansing Assessment and Report},
journal = {Endoscopy International Open},
year = {2026},
volume = {14},
number = {CP},
doi = {10.1055/a-2961-4842}
}
EUVIMED