Digital versus conventional impression accuracy for complete-arch implant rehabilitation: An in vitro study
Bioinformation · 31.03.2026 · 22 (3) · 1854-1859
DOI: 10.6026/973206300221854 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinformation, online erschienen am 31.03.2026. Verfasst von Krishnendhu Sai und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Mar Baselios Dental College, Kothamangalam, Kerala, India. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Accurate implant position transfer remains critical for passive fit in full-arch implant prostheses, particularly challenging with angulated implants in edentulous mandibles. This in vitro study compared ten digital impressions (TRIOS scanner) versus ten conventional splinted open-tray polyether impressions using an edentulous mandibular model with six implants. Three-dimensional deviations were measured via coordinate measuring machine, revealing no statistically significant differences between techniques via independent t-test analysis. Conventional impressions demonstrated slightly superior X- and Y-axis precision, while digital impressions shows marginally better Z-axis trueness, both proves clinically acceptable. These findings advance prosthodontic practice by validating both digital and conventional impression techniques for complete-arch implant rehabilitation while highlighting conventional method predictability for complex cases.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, Mar Baselios Dental College, Kothamangalam, Kerala, India.
Zitieren
APA
Sai, K., Kurian, B. P., Manual, L., Aby, S. S., Anand, S. S., Najeeb, F. M., & Nandakumar, V. (2026). Digital versus conventional impression accuracy for complete-arch implant rehabilitation: An in vitro study. Bioinformation, 22(3), 1854-1859. https://doi.org/10.6026/973206300221854
Vancouver
Sai K, Kurian BP, Manual L, Aby SS, Anand SS, Najeeb FM, et al. Digital versus conventional impression accuracy for complete-arch implant rehabilitation: An in vitro study. Bioinformation. 2026;22(3):1854-1859. doi:10.6026/973206300221854
BibTeX
@article{Sai2026,
author = {Sai, Krishnendhu and Kurian, Byju Paul and Manual, Litto and Aby, Shalu Sara and Anand, Sandra S and Najeeb, Fathima Mohamad and Nandakumar, Vrinda},
title = {Digital versus conventional impression accuracy for complete-arch implant rehabilitation: An in vitro study},
journal = {Bioinformation},
year = {2026},
volume = {22},
number = {3},
pages = {1854--1859},
doi = {10.6026/973206300221854}
}
EUVIMED