EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC-ND 4.0

Custom PEKK Triflange Implant for Reconstruction of a Post-infectious Acetabular Defect: A Case Report

Jon Minter, MD, Georgiana Hopper, MD

Journal of Orthopaedic Experience & Innovation · 04.06.2026 · 7 (1)

DOI: 10.60118/001c.161156 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Orthopaedic Experience & Innovation, online erschienen am 04.06.2026. Verfasst von Jon Minter und 3 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Complex acetabular defects with associated infection as well as multiple revision procedures remain a significant reconstructive challenge due to compromised bone stock, altered anatomy, and increased risk of recurrent infection. Custom triflange implants have been used to restore pelvic stability in severe bone loss; however, conventional metallic constructs may present limitations in previously infected environments, including challenges with imaging assessment and biomechanical load transfer. Patient-specific implants manufactured from Poly Ether Ketone Ketone (PEKK), a high-performance polymer with mechanical properties closer to cortical bone, may offer an alternative reconstructive strategy. Case Presentation We report the case of a patient with a traumatic acetabular defect following multiple prior surgeries complicated by infection. Following radiographic studies and assessment for potential infection a patient-specific PEKK triflange implant was designed using computed tomography–based preoperative planning. The implant was inserted through a direct lateral approach with fixation tailored to remaining host bone to restore the hip center of rotation and pelvic continuity.

Results

The implant achieved stable fixation with appropriate alignment. Early postoperative imaging confirmed accurate positioning and construct stability. At most recent follow-up of approximately 7 months, the construct remains stable, with no evidence of loosening or recurrent infection. The patient demonstrated satisfactory early clinical recovery without immediate postoperative complications.

Conclusion

This case demonstrates the feasibility of a custom PEKK triflange implant for reconstruction of severe post-infectious acetabular bone loss. Patient-specific polymer-based implants may represent a viable reconstructive option in complex revision cases in which traditional metallic implants present limitations. Further investigation is warranted to evaluate long-term outcomes and overall clinical applicability.

Zitieren

APA

Minter, J., MD, Hopper, G., & MD (2026). Custom PEKK Triflange Implant for Reconstruction of a Post-infectious Acetabular Defect: A Case Report. Journal of Orthopaedic Experience & Innovation, 7(1). https://doi.org/10.60118/001c.161156

Vancouver

Minter J, MD, Hopper G, MD. Custom PEKK Triflange Implant for Reconstruction of a Post-infectious Acetabular Defect: A Case Report. Journal of Orthopaedic Experience & Innovation. 2026;7(1). doi:10.60118/001c.161156

BibTeX
@article{Minter2026,
  author = {Minter, Jon and MD and Hopper, Georgiana and MD},
  title = {Custom PEKK Triflange Implant for Reconstruction of a Post-infectious Acetabular Defect: A Case Report},
  journal = {Journal of Orthopaedic Experience & Innovation},
  year = {2026},
  volume = {7},
  number = {1},
  doi = {10.60118/001c.161156}
}
Kostenlos starten →