EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access · CC BY-NC 4.0

Custom triflange acetabular components for large acetabular defect reconstruction in revision total hip arthroplasty: a systematic review and meta-analysis on 1218 patients

Demien Broekhuis iD, Rutger Tordoir iD, Zoe Vallinga, Jan Schoones iD, Bart Pijls iD, Rob Nelissen iD

EFORT Open Reviews · 01.07.2023 · 8 (7) · 522-531

DOI: 10.1530/eor-22-0081 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift EFORT Open Reviews, erschienen am 01.07.2023. Verfasst von Demien Broekhuis und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This is a systematic review and meta(regression) analysis to assess the performance of custom triflange acetabular components (CTAC) in total hip arthroplasty (THA) revision surgery. Implant-related complications, failure rate, functional outcomes and implant and surgical technique-related predictors for outcome were assessed.

Methods

This systematic review was performed according to PRISMA guidelines and registered with PROSPERO (2020 CRD42020209700). PubMed, Embase, Web of Science, COCHRANE Library and Emcare were searched. Studies on Paprosky type 3A and 3B or AAOS type 3 and 4 acetabular defects with a minimum follow-up of 12 months and cohorts > 10 patients were included.

Results

Thirty-three studies were eligible for inclusion ( n = 1235 hips, 1218 patients). The methodological quality of the studies was moderate (AQUILA: 7.4/11 points). Considerable heterogeneity was observed in terms of complications, re-operations and implant failure reporting. The total incidence of implant-related complications was 24%. The incidence of re-operation for any reason was 15%, and the implant failure rate was 12% at a mean of 46.9 months and the post-operative Harris Hip Score improved by a mean of 40 points. Several predictors for outcome were found, such as implant generation, follow-up length and study start date.

Conclusions

The use of CTAC in revision THA has satisfactory complication and implant failure rates. The CTAC technique improves post-operative clinical outcomes and the meta-regression analysis showed that there is a clear association between improvements in the CTAC performance and the evolvement of this technique over time.

Schlagwörter

Stichwörter der Autor:innen

custom triflange acetabular componentlarge acetabular defectstotal hip arthroplasty revision

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands.

ORCID-Profile: Demien Broekhuis, Rutger Tordoir, Jan Schoones, Bart Pijls, Rob Nelissen

Zitieren

APA

Broekhuis, D., Tordoir, R., Vallinga, Z., Schoones, J., Pijls, B., & Nelissen, R. (2023). Custom triflange acetabular components for large acetabular defect reconstruction in revision total hip arthroplasty: a systematic review and meta-analysis on 1218 patients. EFORT Open Reviews, 8(7), 522-531. https://doi.org/10.1530/eor-22-0081

Vancouver

Broekhuis D, Tordoir R, Vallinga Z, Schoones J, Pijls B, Nelissen R. Custom triflange acetabular components for large acetabular defect reconstruction in revision total hip arthroplasty: a systematic review and meta-analysis on 1218 patients. EFORT Open Reviews. 2023;8(7):522-531. doi:10.1530/eor-22-0081

BibTeX
@article{Broekhuis2023,
  author = {Broekhuis, Demien and Tordoir, Rutger and Vallinga, Zoe and Schoones, Jan and Pijls, Bart and Nelissen, Rob},
  title = {Custom triflange acetabular components for large acetabular defect reconstruction in revision total hip arthroplasty: a systematic review and meta-analysis on 1218 patients},
  journal = {EFORT Open Reviews},
  year = {2023},
  volume = {8},
  number = {7},
  pages = {522--531},
  doi = {10.1530/eor-22-0081}
}
Kostenlos starten →