EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

The Accuracy of Mechanical Axis Measurements with an Image-based Robotic Total Knee Arthroplasty System

Keith M. Baumgarten

Journal of Orthopaedic Experience & Innovation · 28.07.2026 · 7 (1)

DOI: 10.60118/001c.159341 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Experience & Innovation, online erschienen am 28.07.2026. Verfasst von Keith M. Baumgarten. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Studies that examine the image-based Rosa robotic knee arthroplasty system in restoring the desired mechanical axis (MA) are rare. The purpose of this study was to measure the accuracy of an image-based robotic knee system in restoring the desired MA.

Methods

Inclusion criteria was patients undergoing an imaged-based total knee arthroplasty with preoperative and postoperative long-leg standing radiographs. Six measurements were analyzed: 1) preoperative radiographically-determined MA (PreopRadMA), 2) preoperative industry/software-determined MA (PreopSoftMA), 3) robotically-determined native MA (PreopRobMA), 4) intraoperatively-planned MA (PlanMA), 5) intraoperative MA after-implant-cementation (IntraopMA), and 6) 2-week-postoperative radiographic MA (PostopRadMA). An outlier was defined when there was greater than 3⁰ between MA measurements.

Results

There was excellent agreement among preoperative measurements, poor-to-moderate agreements between planned MA and IntraopMA and PostopRadMA, and good-to-excellent agreement comparing IntraopMA with PostopRadMA. The IntraopMA and PostopRadMA deviated from the PlanMA by 1.4±1.1⁰ (4% outliers) and 1.6±1.3⁰ (14% outliers), respectively. The PostopRadMA differed from the IntraopMA by 1.5±1.2⁰ (8% outliers). There were greater differences found in the mean variances and outlier percentages between the 1) PreopRadMA and PreopRobMA (2.8±2.0⁰; p

Zitieren

APA

Baumgarten, K. M. (2026). The Accuracy of Mechanical Axis Measurements with an Image-based Robotic Total Knee Arthroplasty System. Journal of Orthopaedic Experience & Innovation, 7(1). https://doi.org/10.60118/001c.159341

Vancouver

Baumgarten KM. The Accuracy of Mechanical Axis Measurements with an Image-based Robotic Total Knee Arthroplasty System. Journal of Orthopaedic Experience & Innovation. 2026;7(1). doi:10.60118/001c.159341

BibTeX
@article{Baumgarten2026,
  author = {Baumgarten, Keith M.},
  title = {The Accuracy of Mechanical Axis Measurements with an Image-based Robotic Total Knee Arthroplasty System},
  journal = {Journal of Orthopaedic Experience & Innovation},
  year = {2026},
  volume = {7},
  number = {1},
  doi = {10.60118/001c.159341}
}
Kostenlos starten →