Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, online erschienen am 06.09.2023. Verfasst von Dennis King-Hang Yee und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Tai Po, Hong Kong. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
This study investigated the accuracy in achieving proper lower limb alignment and component positions after total knee replacement (TKR) with image‐free and image‐based robotic‐assisted TKR.
Methods
A total of 129 patients (166 knees) suffering from end‐stage knee arthritis who underwent TKA operated by robotic‐assisted surgery between the years 2018 and mid‐2021 were recruited. Radiological outcomes were compared between image‐free and image‐based robotic‐assisted surgical systems.
Results
There were significant differences between the two robotic systems when comparing the mean planned component alignment and the mean measured alignment on radiographs, in which the image‐free robotic‐assisted system was more varus, whereas the image‐based robotic‐assisted system was more valgus for both the mean femoral and tibial component coronal alignment ( p < 0.001). For tibial component sagittal alignment, the image‐based group had a larger deviation from the planned posterior slope ( p < 0.001).
Conclusion
Image‐free and image‐based robotic assisted TKR had differing accuracy in femoral and tibial alignment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Tai Po, Hong Kong.
- Department of Orthopaedics and Traumatology, Prince of Wales Hospital, Shatin, Hong Kong.
- Department of Orthopaedics and Traumatology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, Hong Kong.
- Office of Research and Knowledge Transfer Services, The Chinese University of Hong Kong, Shatin, Hong Kong.
ORCID-Profile: Dennis King-Hang Yee, Cyrus Tsun-Kit Lau
Zitieren
APA
Yee, D. K., Ng, J. P., Lau, C. T., Ho, K. K., Man, G. C., Chu, V. W., Choi, T. L., Lam, G. Y. T., Ong, M. T., & Yung, P. S. (2024). Surgical accuracy of image‐free versus image‐based robotic‐assisted total knee arthroplasty. The International Journal of Medical Robotics and Computer Assisted Surgery, 20(1). https://doi.org/10.1002/rcs.2574
Vancouver
Yee DK, Ng JP, Lau CT, Ho KK, Man GC, Chu VW, et al. Surgical accuracy of image‐free versus image‐based robotic‐assisted total knee arthroplasty. The International Journal of Medical Robotics and Computer Assisted Surgery. 2024;20(1). doi:10.1002/rcs.2574
BibTeX
@article{Yee2024,
author = {Yee, Dennis King-Hang and Ng, Jonathan Patrick and Lau, Cyrus Tsun-Kit and Ho, Kevin Ki-Wai and Man, Gene Chi-Wai and Chu, Vikki Wing-Shan and Choi, Tsz Lung and Lam, Gloria Yan Ting and Ong, Michael Tim-Yun and Yung, Patrick Shu-Hang},
title = {Surgical accuracy of image‐free versus image‐based robotic‐assisted total knee arthroplasty},
journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
year = {2024},
volume = {20},
number = {1},
doi = {10.1002/rcs.2574}
}
EUVIMED