Imageless and image‐based robotic‐assisted total knee arthroplasty achieve equivalent radiographic accuracy: A randomised controlled trial
Knee Surgery, Sports Traumatology, Arthroscopy · 2026-06 · 34 (6) · 2167-2179
DOI: 10.1002/ksa.70123 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 22.10.2025. Verfasst von Rapeepat Narkbunnam und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkoknoi, Bangkok, Thailand. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Osteoarthritis, Knee. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Medical Council of Thailand.
Abstract (Originalsprache)
Purpose
Robotic‐assisted total knee arthroplasty systems offer both image‐based and imageless workflows, but their comparative accuracy remains unclear. The robotic surgical assistant (ROSA) system uniquely provides both approaches within a single platform. This study compared radiographic accuracy between image‐based and imageless ROSA‐assisted total knee arthroplasty (ROSA‐TKA).
Methods
This double‐blind, randomised controlled trial included patients with primary knee osteoarthritis randomised to imageless ( n = 47) versus image‐based ( n = 48) ROSA‐TKA. Primary outcomes assessed the differences between final intraoperative planned measurements (FIPM), robotic‐validated measurements (RVM) after bone cuts and postoperative scannogram measurements (PSM) across five radiographic alignment parameters measured at 12 weeks: hip‐knee‐ankle angle, femoral coronal and sagittal alignment, tibial coronal alignment and tibial slope. Secondary outcomes included functional scores and complications.
Results
Both techniques demonstrated equivalent radiographic accuracy with no significant differences between groups. Mean differences between FIPM and RVM were ≤1 degree for all parameters, achieving 93.6%–100% accuracy within 2‐degree thresholds. No significant differences were observed between imageless and image‐based approaches in comparisons of FIPM and RVM with postoperative scanograms. However, these comparisons showed larger differences (1.2–2.5 degrees) and lower accuracy rates (48.9%–87.5% within 2‐degree thresholds), with sagittal alignment showing the greatest variation. Functional outcomes improved equally in both groups at 6 and 12 weeks, with comparable registration times and no complications.
Conclusion
Both imageless and image‐based ROSA‐TKA achieved equivalent radiographic accuracy and clinical outcomes. The choice between techniques should be based on practical workflow considerations rather than accuracy concerns, as both approaches deliver comparable precision and excellent safety profiles. Clinical Trial Registration This study was registered in the Thai Clinical Trials Registry (TCTR20240614001). Level of Evidence Level I.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkoknoi, Bangkok, Thailand.
ORCID-Profile: Rapeepat Narkbunnam, Yotsawadee Chorunchan, Keerati Chareancholvanich, Chaiwat Achawakulthep, Kit Awirotananon, Chaturong Pornrattanamaneewong
Förderung
- The Medical Council of Thailand
Zitieren
APA
Narkbunnam, R., Chorunchan, Y., Chareancholvanich, K., Achawakulthep, C., Awirotananon, K., & Pornrattanamaneewong, C. (2026). Imageless and image‐based robotic‐assisted total knee arthroplasty achieve equivalent radiographic accuracy: A randomised controlled trial. Knee Surgery, Sports Traumatology, Arthroscopy, 34(6), 2167-2179. https://doi.org/10.1002/ksa.70123
Vancouver
Narkbunnam R, Chorunchan Y, Chareancholvanich K, Achawakulthep C, Awirotananon K, Pornrattanamaneewong C. Imageless and image‐based robotic‐assisted total knee arthroplasty achieve equivalent radiographic accuracy: A randomised controlled trial. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(6):2167-2179. doi:10.1002/ksa.70123
BibTeX
@article{Narkbunnam2026,
author = {Narkbunnam, Rapeepat and Chorunchan, Yotsawadee and Chareancholvanich, Keerati and Achawakulthep, Chaiwat and Awirotananon, Kit and Pornrattanamaneewong, Chaturong},
title = {Imageless and image‐based robotic‐assisted total knee arthroplasty achieve equivalent radiographic accuracy: A randomised controlled trial},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2026},
volume = {34},
number = {6},
pages = {2167--2179},
doi = {10.1002/ksa.70123}
}
EUVIMED