EUVIMEDEUVIMED entdecken
Crossref

Quantitative Evaluation of Evacuation Criteria Based on Scattered Radiation Shielding Performance of a Protective Screen during Portable Dynamic Chest Radiography

Yuki Sato, Kojiro Ono, Kana Hatsumi, Koshiro Takuma, Junichi Matsumoto, Takafumi Haraguchi, Nagaharu Takakura

Japanese Journal of Radiological Technology · 2026

DOI: 10.6009/jjrt.26-1570 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2026. Verfasst von Yuki Sato und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, St. Marianna University Hospital. Hauptthemen laut MEDLINE: Radiation Protection, Radiography, Thoracic. Die Arbeit nennt 18 Literaturangaben. Gefördert von: KONICA MINOLTA, INC..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Portable dynamic chest radiography (DCR) offers high clinical utility but also raises concerns about increased scattered radiation exposure to surrounding personnel. This study aimed to optimize radiation protection by quantitatively assessing the shielding performance of a protective screen and by evaluating evacuation criteria. METHODS: Scattered radiation was measured using an anthropomorphic phantom and an ionization chamber-type survey meter under various imaging conditions, with and without a mobile protective screen (0.25 mmPb equivalent). Four quantitative indicators were introduced: dose reduction ratio (DR ratio), evacuation area (EA), evacuation area ratio (EA ratio), and evacuation distance (ED). RESULTS: Use of the protective screen reduced scattered radiation by over 80%, expanded the EA by up to 55.5%, and shortened the ED by more than 100 cm. These findings indicate its effectiveness in creating safer imaging environments in limited spaces. CONCLUSION: The proposed indicators provide an objective method for assessing the shielding performance of protective screens in portable DCR. These results support the development of evacuation criteria to reduce exposure for healthcare workers and nearby patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ProtectionRadiography, ThoracicHumansPhantoms, ImagingScattering, RadiationRadiation Dosage

Stichwörter der Autor:innen

conventional chest radiographydynamic chest radiographyportable X-rayradiation protectionscattered X-ray distribution

Autor:innen und Institutionen

  • Department of Radiological Technology, St. Marianna University Hospital.
  • Advanced Image Development Division, Medical Imaging R&D Center, Healthcare Business Headquarters, KONICA MINOLTA, INC.
  • Department of Emergency and Critical Care Medicine, St. Marianna University School of Medicine.
  • Department of Diagnostic and Interventional Radiology, St. Marianna University School of Medicine.

Förderung

  • KONICA MINOLTA, INC.

Zitieren

APA

Sato, Y., Ono, K., Hatsumi, K., Takuma, K., Matsumoto, J., Haraguchi, T., & Takakura, N. (2026). Quantitative Evaluation of Evacuation Criteria Based on Scattered Radiation Shielding Performance of a Protective Screen during Portable Dynamic Chest Radiography. Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.26-1570

Vancouver

Sato Y, Ono K, Hatsumi K, Takuma K, Matsumoto J, Haraguchi T, et al. Quantitative Evaluation of Evacuation Criteria Based on Scattered Radiation Shielding Performance of a Protective Screen during Portable Dynamic Chest Radiography. Japanese Journal of Radiological Technology. 2026. doi:10.6009/jjrt.26-1570

BibTeX
@article{Sato2026,
  author = {Sato, Yuki and Ono, Kojiro and Hatsumi, Kana and Takuma, Koshiro and Matsumoto, Junichi and Haraguchi, Takafumi and Takakura, Nagaharu},
  title = {Quantitative Evaluation of Evacuation Criteria Based on Scattered Radiation Shielding Performance of a Protective Screen during Portable Dynamic Chest Radiography},
  journal = {Japanese Journal of Radiological Technology},
  year = {2026},
  doi = {10.6009/jjrt.26-1570}
}
Kostenlos starten →