Evaluation of the Latest Motion Correction Techniques in Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) Imaging across Different Vendors
Japanese Journal of Radiological Technology · 2024
DOI: 10.6009/jjrt.2024-1520 ↗Kurz gefasst
Fachartikel in der Zeitschrift Japanese Journal of Radiological Technology, 2024. Verfasst von Yuma Takahashi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Fukushima Medical University Hospital. Hauptthemen laut MEDLINE: Phantoms, Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate the robustness of the latest periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technology from each vendor against head movements and to investigate their characteristics for effective clinical use. METHODS: Using a phantom simulating the T2-weighted image of the human brain, images were acquired with devices from CANON MEDICAL SYSTEMS (Tochigi, Japan; hereinafter "Canon"), GE HealthCare (Chicago, IL, USA; hereinafter "GE"), Philips (Amsterdam, Netherlands), and Siemens Healthineers (Forchheim, Germany; hereinafter "SIEMENS"). The head motion patterns were divided into rotation angle dependency (single rotation and multiple rotations) and rotation frequency dependency and evaluated using structural similarity (SSIM). RESULTS: For rotation angle dependency, Canon was robust against small rotation angles and fine movements. Despite the rotation angle, GE was robust against movements, with deep learning reconstruction (DLR) improving correction functionality. Philips could be used with compressed sensitivity encoding (CS), and robustness varied with blade width. SIEMENS was robust against large movements. For rotation frequency dependency, results were similar across the 4 vendors. CONCLUSION: The rotation angle and rotation frequency dependencies of the PROPELLER technology from the 4 vendors were quantitatively evaluated. Understanding the characteristics of PROPELLER allows for the possibility of providing diagnostic-quality images even for patients who move during head MRI exams by appropriately using PROPELLER.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Fukushima Medical University Hospital.
- Graduate School of Ibaraki Prefectural University of Health Sciences.
- Department of Radiological Technology, Tohoku University Hospital.
- Department of Radiology, Yokohama Sekishinkai Hospital.
- Department of Radiology, Kawasaki Saiwai Hospital.
- Department of Radiology, Otaru General Hospital.
Zitieren
APA
Takahashi, Y., Ishikawa, H., Nemoto, H., Yokoshima, K., Sasahara, D., Naka, T., Oura, D., Matsumoto, K., & Saotome, K. (2024). Evaluation of the Latest Motion Correction Techniques in Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) Imaging across Different Vendors. Japanese Journal of Radiological Technology. https://doi.org/10.6009/jjrt.2024-1520
Vancouver
Takahashi Y, Ishikawa H, Nemoto H, Yokoshima K, Sasahara D, Naka T, et al. Evaluation of the Latest Motion Correction Techniques in Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) Imaging across Different Vendors. Japanese Journal of Radiological Technology. 2024. doi:10.6009/jjrt.2024-1520
BibTeX
@article{Takahashi2024,
author = {Takahashi, Yuma and Ishikawa, Hironobu and Nemoto, Hitoshi and Yokoshima, Kengo and Sasahara, Daiki and Naka, Takanori and Oura, Daisuke and Matsumoto, Koji and Saotome, Kosaku},
title = {Evaluation of the Latest Motion Correction Techniques in Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) Imaging across Different Vendors},
journal = {Japanese Journal of Radiological Technology},
year = {2024},
doi = {10.6009/jjrt.2024-1520}
}
EUVIMED