EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Thermodynamic investigation of a diffusion absorption refrigeration system with an isobutane–dimethylformamide–helium working fluid blend

Sreenesh Valiyandi, Gireeshkumaran Thampi

Energy Storage and Conversion · 12.03.2026

DOI: 10.59400/esc4043 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energy Storage and Conversion, online erschienen am 12.03.2026. Verfasst von Sreenesh Valiyandi und 1 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diffusion absorption refrigeration (DAR) is a promising cycle concerning renewable energy utilization, as the cycle can operate using only thermal energy input. However, to realize the benefits of the DAR cycle, there is a need to develop an improved understanding of how design parameters influence its performance. The cycle’s performance was particularly sensitive to several factors: the rate of heat added and the temperature of the generator, the effectiveness of the gas and solution heat exchangers, the mass flow rate of the refrigerant, and the type of working fluid. The aim of this research work is to conduct numerical simulations of the diffusion absorption refrigeration (DAR) cycle to study the thermodynamic performances. The working fluids utilized in this system are isobutane (R600a) (C4H10) as a refrigerant, dimethylformamide (CH3)2NC(O)H, as absorbent and helium as the inert gas. The cycle operation characteristics are investigated through numerical analysis, in terms of the coefficient of performance (COP) and minimum temperature by using the effect of generator temperature, absorber temperature, evaporator temperature and the solution concentrations. The performance of the system is examined by computer simulation using MATLAB software. The mathematical model will provide a reasonable estimation of the maximum COP, cooling capacity, mass flow rate, and exergy analysis. The refrigeration cycle experiments were conducted under the ambient condition of 30 ℃. Based on a mathematical model, performance evaluation and exergy analysis of the system are performed. The experiment set included a 0.04 m3 volume of commercial absorption diffusion refrigerator working with the dimethylformamide (CH3)2NC(O)H solution. Furthermore, the results obtained in the proposed system compare with the previous studies.

Zitieren

APA

Valiyandi, S., & Thampi, G. (2026). Thermodynamic investigation of a diffusion absorption refrigeration system with an isobutane–dimethylformamide–helium working fluid blend. Energy Storage and Conversion. https://doi.org/10.59400/esc4043

Vancouver

Valiyandi S, Thampi G. Thermodynamic investigation of a diffusion absorption refrigeration system with an isobutane–dimethylformamide–helium working fluid blend. Energy Storage and Conversion. 2026. doi:10.59400/esc4043

BibTeX
@article{Valiyandi2026,
  author = {Valiyandi, Sreenesh and Thampi, Gireeshkumaran},
  title = {Thermodynamic investigation of a diffusion absorption refrigeration system with an isobutane–dimethylformamide–helium working fluid blend},
  journal = {Energy Storage and Conversion},
  year = {2026},
  doi = {10.59400/esc4043}
}
Kostenlos starten →