Thermodynamic performance of an ejector–compressor enhanced diffusion–absorption refrigeration system for cement kiln waste heat recovery

Baby-Jean Robert Mungyeko Bisulandu, Marcel Tsimba Mboko, Lucien Mbozi Mbozi, Daniel R. Rousse, Adrian Ilinca

Transactions of the Canadian Society for Mechanical Engineering · 01.01.2026 · 50 · 1-20

DOI: 10.1139/tcsme-2025-0249 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Transactions of the Canadian Society for Mechanical Engineering, erschienen am 01.01.2026. Verfasst von Baby-Jean Robert Mungyeko Bisulandu und 4 weiteren Autor:innen. Die Arbeit nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The growing scarcity and rising costs of fossil fuels are accelerating the global transition toward energy-efficient, low-emission industrial systems. Cement plants reject large amounts of thermal energy through exhaust gases, offering an opportunity for heat recovery. This study investigates the thermodynamic performance of a diffusion–absorption refrigeration (DAR) system enhanced with an ejector and a compressor (DAR-EC) and powered by residual heat from a cement kiln. The system is modelled using the M2EP framework (mass, energy, exergy, and performance) and optimized through a particle swarm algorithm. The particle swarm optimization algorithm identifies optimal pressure and concentration levels that maximize coefficient of performance, subject to constraints on the low-temperature heat source. The working fluid is a ternary H 2 O–NH 3 –H 2 mixture, enabling continuous circulation between the evaporator and absorber. Integrating the ejector and compressor increases the operating pressure at the evaporator outlet and the absorber inlet, thereby improving cycle performance. A sensitivity analysis to temperature, concentration, and pressure variations is performed. Results show that the DAR-EC configuration significantly increases the cooling capacity and raises the coefficient of performance from 0.27 (DAR) to 0.49 (DAR-EC). Exergy analysis additionally reveals that generator and absorber irreversibilities dominate system losses. The model is validated against published data and demonstrates its suitability for industrial heat-recovery applications. The findings provide a decision-support basis for implementing DAR-EC systems to valorize waste heat. Given that this model uses a water-ammonia mixture, the heat source temperature must be between 80 and 200 °C.

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Bisulandu, B. R. M., Mboko, M. T., Mbozi, L. M., Rousse, D. R., & Ilinca, A. (2026). Thermodynamic performance of an ejector–compressor enhanced diffusion–absorption refrigeration system for cement kiln waste heat recovery. Transactions of the Canadian Society for Mechanical Engineering, 50, 1-20. https://doi.org/10.1139/tcsme-2025-0249

Vancouver

Bisulandu BRM, Mboko MT, Mbozi LM, Rousse DR, Ilinca A. Thermodynamic performance of an ejector–compressor enhanced diffusion–absorption refrigeration system for cement kiln waste heat recovery. Transactions of the Canadian Society for Mechanical Engineering. 2026;50:1-20. doi:10.1139/tcsme-2025-0249

BibTeX
@article{Bisulandu2026,
  author = {Bisulandu, Baby-Jean Robert Mungyeko and Mboko, Marcel Tsimba and Mbozi, Lucien Mbozi and Rousse, Daniel R. and Ilinca, Adrian},
  title = {Thermodynamic performance of an ejector–compressor enhanced diffusion–absorption refrigeration system for cement kiln waste heat recovery},
  journal = {Transactions of the Canadian Society for Mechanical Engineering},
  year = {2026},
  volume = {50},
  pages = {1--20},
  doi = {10.1139/tcsme-2025-0249}
}
Kostenlos starten →