EUVIMEDEUVIMED entdecken
Crossref

Adaptive Closed-Loop Runtime Control for Non-Destructive Testing Instruments

Matthew Stanley Leibel

e-Journal of Nondestructive Testing · 2026-07 · 31 (7)

DOI: 10.58286/33975 ↗

Kurz gefasst

Fachartikel in der Zeitschrift e-Journal of Nondestructive Testing, 2026-07. Verfasst von Matthew Stanley Leibel.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Modern non-destructive testing (NDT) instruments are increasingly software-defined, datarich, and multitechnology-capable, yet many are still operated predominantly in open loop: settings are calibrated, inspection begins, and the environment is then allowed to vary underneath a largely fixed parameter set. This paper presents Interference- Feedback Computing (IFC) at a high level as a lightweight closed-loop runtime concept for NDT instrumentation. IFC is framed not as a replacement for existing inspection platforms, but as a local adaptive layer that updates a bounded subset of operating parameters from live measurement statistics. A public-spec proxy simulation study was conducted across seven representative workflows spanning phased-array ultrasonics, advanced ultrasonic imaging, automated weld inspection, handheld eddy-current inspection, eddy-current array inspection, and corrosion mapping. The modeled results indicate that adaptive runtime control creates little value on easy inspections but becomes increasingly useful once coupling, lift-off, attenuation, geometry, surface state, scan stability, or field noise begin to drift away from the assumptions embedded in a fixed nominal setup. Across the seven workflows, the strongest modeled severecondition uplifts ranged from 11.4% to 31.8%. To strengthen conference suitability, the simulation methodology is stated explicitly: each workflow was evaluated over 250 seeded Monte Carlo perturbation runs per operating regime, and performance was summarized through a normalized composite inspection score built from signal quality, control stability, and operational efficiency surrogates. The results support a practical thesis: many modern NDT systems already contain the sensing substrate, embedded computation, and writable operating surfaces needed for bounded local adaptation. A runtime layer such as IFC therefore merits pilot evaluation as a means of improving inspection stability and performance without requiring new hardware.

Zitieren

APA

Leibel, M. S. (2026). Adaptive Closed-Loop Runtime Control for Non-Destructive Testing Instruments. e-Journal of Nondestructive Testing, 31(7). https://doi.org/10.58286/33975

Vancouver

Leibel MS. Adaptive Closed-Loop Runtime Control for Non-Destructive Testing Instruments. e-Journal of Nondestructive Testing. 2026;31(7). doi:10.58286/33975

BibTeX
@article{Leibel2026,
  author = {Leibel, Matthew Stanley},
  title = {Adaptive Closed-Loop Runtime Control for Non-Destructive Testing Instruments},
  journal = {e-Journal of Nondestructive Testing},
  year = {2026},
  volume = {31},
  number = {7},
  doi = {10.58286/33975}
}
Kostenlos starten →