A Closed-Loop Measurement Study of Runtime Governance in AI-Driven Smart Building Climate Control

Norkobil Saydirasulov Saydirasulovich iD, Dilmurod Abdujalilovich Davronbekov iD, Makhmudov Makhsum Mubashirovich, Young Im Cho iD

Sensors · 04.08.2026 · 26 (15) · 4921

DOI: 10.3390/s26154921 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 04.08.2026. Verfasst von Norkobil Saydirasulov Saydirasulovich und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Engineering, Gachon University, Sujeong-gu, Seongnam-si 461-701, Gyeonggi-do, Republic of Korea. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Institute for Advancement of Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Which runtime governance mechanisms reduce physical risk when a learned controller drives a building’s climate, and under what conditions? We develop a closed-loop software-in-the-loop testbed in which a setpoint model trained on real occupancy data drives a physics-based thermal zone through a declarative governance plane, with outcomes scored by an independent safety oracle, and we run the same governance logic on a real MQTT stack with an in-process policy decision point and a hash-chained audit log. Under distribution shift, admission control reduces unsafe physical exposure by 19.4%, from 1185.3 to 954.8 °C·min, whereas adding checkpoint rollback reduces it by only a further 0.2% in the reference run (0.1–0.4% across sensor noise seeds): the governance decision takes 0.44 ms while physical recovery takes a median of 61 min. Prevention therefore outperforms recovery in the studied thermal system, and the remaining avoidable exposure is driven by the policy’s estimate of occupancy context. A deterministic single-rule thermostat incurs 50% more exposure under shift while the learned controller uses a 38% higher heating demand proxy: a safety–demand trade-off, not evidence that learned control is necessary. A plant sweep yields an operating envelope criterion for inertial plants: rollback contributes materially to safety only when the plant is restored before the next command arrives and sampled before it can leave the safe set; on slower plants it removes at most 14.7%, with a transition band in between. No physical hardware was operated.

Schlagwörter

Stichwörter der Autor:innen

AI governanceIoT runtime governanceadmission controlclosed-loop testbeddistribution shiftreproducibilityresidual riskrobustness analysisrollbacksafety oracle

Autor:innen und Institutionen

  • Department of Computer Engineering, Gachon University, Sujeong-gu, Seongnam-si 461-701, Gyeonggi-do, Republic of Korea.
  • Department of Engineering and Communications, ZARMED University, Samarkand Campus, Khodja Akhror Vali Street 23, Samarkand 140100, Uzbekistan.
  • Department of Technologies of Mobile Communication, Tashkent University of Information Technologies Named After Muhammad Al-Khwarizmi, Tashkent 100084, Uzbekistan.
  • Scientific and Innovation Center of Information and Communication Technologies "UNICON.UZ" LLC, Tashkent 100187, Uzbekistan.

ORCID-Profile: Norkobil Saydirasulov Saydirasulovich, Dilmurod Abdujalilovich Davronbekov, Young Im Cho

Förderung

  • Korea Institute for Advancement of Technology

Zitieren

APA

Saydirasulovich, N. S., Davronbekov, D. A., Mubashirovich, M. M., & Cho, Y. I. (2026). A Closed-Loop Measurement Study of Runtime Governance in AI-Driven Smart Building Climate Control. Sensors, 26(15), 4921. https://doi.org/10.3390/s26154921

Vancouver

Saydirasulovich NS, Davronbekov DA, Mubashirovich MM, Cho YI. A Closed-Loop Measurement Study of Runtime Governance in AI-Driven Smart Building Climate Control. Sensors. 2026;26(15):4921. doi:10.3390/s26154921

BibTeX
@article{Saydirasulovich2026,
  author = {Saydirasulovich, Norkobil Saydirasulov and Davronbekov, Dilmurod Abdujalilovich and Mubashirovich, Makhmudov Makhsum and Cho, Young Im},
  title = {A Closed-Loop Measurement Study of Runtime Governance in AI-Driven Smart Building Climate Control},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {15},
  pages = {4921},
  doi = {10.3390/s26154921}
}
Kostenlos starten →