Low-temperature electrocautery for high-risk cardiac implantable electronic device procedures

Maciej Dyrbuś, Anna Kurek, Katarzyna Sokoła, Jacek T Niedziela, Mateusz Ostręga, Daniel Cieśla, Mariusz Gąsior, Mateusz Tajstra

Cardiology Journal · 2024

DOI: 10.5603/cj.94123 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiology Journal, 2024. Verfasst von Maciej Dyrbuś und 7 weiteren Autor:innen. Beteiligte Einrichtung: 3rd Department of Cardiology, School of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland. mdyrbus@op.pl. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Pacemaker, Artificial. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With rising numbers of cardiac implantable electronic devices (CIEDs) implanted each year, the population of patients with those devices is growing extensively [1].Large numbers of those patients will eventually require secondary procedures, including device replacements, or upgrades.As during past years , the implanted systems become surrounded by adhesive tissue and fibers, the secondary procedures have been historically associated with a higher risk of short-and long-term complications, most often including lead damage.Moreover, due to comorbidities, a high percentage of patients with CIEDs are treated nowadays with anticoagulants, which increases the risk of bleeding and pocket hematoma.Thus, electrocautery is used to mitigate the risk of periprocedural bleeding.However, the use of conventional electrocautery can risk lead dysfunction due to its thermal injury.The low-temperature electrocautery has been proven to improve local outcomes [2].Few reports were published to date on its utilization in CIED-related procedures [3][4][5].The aim of this analysis was to summarize its safety and efficacy in higher complication-risk procedures performed in a tertiary Polish center.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantablePacemaker, ArtificialHumansTemperatureElectrocoagulationElectronics

Autor:innen und Institutionen

  • 3rd Department of Cardiology, School of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland. mdyrbus@op.pl.
  • 3rd Department of Cardiology, School of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland.
  • Department of Science and New Technologies, Silesian Center for Heart Diseases, Zabrze, Poland.

Zitieren

APA

Dyrbuś, M., Kurek, A., Sokoła, K., Niedziela, J. T., Ostręga, M., Cieśla, D., Gąsior, M., & Tajstra, M. (2024). Low-temperature electrocautery for high-risk cardiac implantable electronic device procedures. Cardiology Journal. https://doi.org/10.5603/cj.94123

Vancouver

Dyrbuś M, Kurek A, Sokoła K, Niedziela JT, Ostręga M, Cieśla D, et al. Low-temperature electrocautery for high-risk cardiac implantable electronic device procedures. Cardiology Journal. 2024. doi:10.5603/cj.94123

BibTeX
@article{Dyrbu2024,
  author = {Dyrbuś, Maciej and Kurek, Anna and Sokoła, Katarzyna and Niedziela, Jacek T and Ostręga, Mateusz and Cieśla, Daniel and Gąsior, Mariusz and Tajstra, Mateusz},
  title = {Low-temperature electrocautery for high-risk cardiac implantable electronic device procedures},
  journal = {Cardiology Journal},
  year = {2024},
  doi = {10.5603/cj.94123}
}
Kostenlos starten →