REINFORCING the clinical utility of an antibacterial envelope to prevent infection following a cardiac implantable electronic device implant procedure
Europace · 2023
DOI: 10.1093/europace/euad260 ↗Kurz gefasst
Editorial in der Zeitschrift Europace, 2023. Verfasst von Suneet Mittal. Beteiligte Einrichtung: Department of Cardiology, The Valley Hospital and the Snyder Center for Comprehensive Atrial Fibrillation, 970 Linwood Avenue, Paramus, NJ 07652, USA. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Pacemaker, Artificial. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
This editorial refers to ‘REducing INFectiOns thRough cardiac device envelope: insight from real world data. The REINFORCE Project’ by M. Ziacchi et al.,https://doi.org/10.1093/eupace/euad224. Infection of cardiac implantable electronic devices (CIEDs) remains an important ongoing issue in clinical practice.1 Once it occurs, treatment typically requires explantation of the implanted hardware; the infection as well as the treatment contributes to morbidity and mortality. Thus, attention has recently focused on strategies at time of device implantation to prevent CIED infection. Towards that end, availability of an antibacterial envelope has been an important advance in the fight against CIED infection. A series of initial observational studies suggested that an antibacterial envelope reduced CIED infection.2–6 The first-generation envelope was non-absorbable; once an absorbable envelope became available (TYRXTM, Medtronic, Minneapolis, MN, USA), the envelope was formally tested in a randomized clinical trial. The Worldwide Randomized Antibiotic Envelope Infection Prevention Trial (WRAP-IT) was a multi-centre, randomized, controlled, prospective, single-blind, post-marketing, interventional clinical trial that compared the incidence of major CIED infections through 12 months after implantation among patients who received an absorbable antibacterial envelope with the incidence among patients who did not receive the envelope.7 Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary endpoint occurred in 25 patients in the envelope group and 42 patients in the control group [12-month Kaplan–Meier estimated event rate, 0.7 and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval (CI), 0.36–0.98; P = 0.04]. Additional analyses have confirmed the safety and efficacy of the envelope in short-term and long-term follow-up, identified risk factors and microbiology of infection, the relationship between pocket haematoma and infection, and the cost-effectiveness of the envelope.8–12 Despite the results of WRAP-IT, several unresolved issues have remained. The first is whether the data can be extrapolated to patients not enrolled in this trial, such as those undergoing de novo pacemaker or defibrillator implantation. The second is whether high-risk patients can be identified who may most benefit from an antibacterial envelope; this issue is largely driven by concerns about the cost of the envelope. The third is whether the findings can be replicated in ‘real-world’ use. In this issue of Europace, Ziacchi et al.13 attempt to answer these questions. This study enrolled consecutive patients undergoing a CIED procedure using a Medtronic device at 11 Italian centres between August 2016 and May 2022. The authors describe the characteristics of the patients in whom an antibacterial envelope was used as well as the impact of the envelope in preventing infection-related events. The decision on whether to use or not use the envelope was left to the discretion of the operator. Overall, 1819 patients were enrolled; an envelope was used in 872 (48%) patients. Two-thirds of patients underwent a de novo procedure, which was a pacemaker in 53% and a defibrillator in 47%. During a mean follow-up of 1.4 ± 1.7 years, there were 27 pocket and 3 systemic infections. Patients who received an envelope had a significantly lower likelihood of infection (0.8 vs. 2.4%, P = 0.007); as in WRAP-IT, the impact of the envelope was largely in preventing pocket infections. Although not statistically significant, likely due to the sample size and lower infection rate in this group, there was also a numerically lower rate of infection in patients undergoing a de novo procedure who received an envelope (0.8 vs. 1.9%, P = 0.130). Notably, a favourable impact of other interventions such as use of antibiotic pocket irrigation and post-operative oral antibiotics was not observed in another study that included de novo patients, where all patients were deemed high-risk and received an antibacterial envelope.14 The study by Ziacchi et al.13 and the WRAP-IT trial suggest that the CIED major infection rate can be reduced to
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Cardiology, The Valley Hospital and the Snyder Center for Comprehensive Atrial Fibrillation, 970 Linwood Avenue, Paramus, NJ 07652, USA.
ORCID-Profile: Suneet Mittal
Zitieren
APA
Mittal, S. (2023). REINFORCING the clinical utility of an antibacterial envelope to prevent infection following a cardiac implantable electronic device implant procedure. Europace. https://doi.org/10.1093/europace/euad260
Vancouver
Mittal S. REINFORCING the clinical utility of an antibacterial envelope to prevent infection following a cardiac implantable electronic device implant procedure. Europace. 2023. doi:10.1093/europace/euad260
BibTeX
@article{Mittal2023,
author = {Mittal, Suneet},
title = {REINFORCING the clinical utility of an antibacterial envelope to prevent infection following a cardiac implantable electronic device implant procedure},
journal = {Europace},
year = {2023},
doi = {10.1093/europace/euad260}
}
EUVIMED