EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Novel nonmagnetic abutment designs for facial prostheses: an experimental study

İrem Sözen Yanik iD, Ufuk Adali iD, Jamila Yassine iD, Franziska Schmidt iD, Wolfgang Hannak iD, Bahadır Ersu iD

Turkish Journal of Medical Sciences · 18.02.2025 · 55 (1) · 152-160

DOI: 10.55730/1300-0144.5953 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Turkish Journal of Medical Sciences, online erschienen am 18.02.2025. Verfasst von İrem Sözen Yanik und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkiye. Hauptthemen laut MEDLINE: Prosthesis Design, Dental Abutments, Prostheses and Implants. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/aim: This in vitro study aimed to evaluate and compare the retentive forces of novel nonmagnetic abutment designs developed as an alternative to conventional magnetic abutments for facial prostheses.Materials and methods: A plexiglass model was constructed and two extraoral implants were placed in these blocks in a parallel position. Nonmagnetic abutments made of titanium were fabricated and screwed onto the implants. The nonmagnetic systems represent a novel design and include two different abutment designs (Type 1 and Type 2) with silicone attachments. Retentive force values for three abutment types: Conventional Magnetic System (CMS), Nonmagnetic abutment Type 1 System (NMS1), and Nonmagnetic abutment Type 2 System (NMS2) were measured at 0th, 120th, 360th, 720th, and 1440th dislodging cycles using a test machine. Given the data's distribution characteristics, non-parametric tests were used for analysis. The Kruskal-Wallis test evaluated significant differences among groups, followed by Dunn's post-hoc test for specific group comparisons. The Friedman test compared the number of dislodging cycles for each group, and the Benjamini-Hochberg adjusted Wilcoxon sign-rank test was used for pairwise comparisons.Results: Both NMS1 and NMS2 groups exhibited significantly higher retentive forces compared to CMS for each of the same dislodging cycles (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis DesignDental AbutmentsProstheses and ImplantsHumansIn Vitro TechniquesTitanium

Stichwörter der Autor:innen

Nonmagnetic abutmentfacial prosthesesimplantmagnetic abutmentmagnetic resonance imaging

Substanzen

Titanium

Autor:innen und Institutionen

  • Department of Prosthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkiye.
  • Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Faculty of Dentistry, Charité University, Berlin, Germany.

ORCID-Profile: İrem Sözen Yanik, Ufuk Adali, Jamila Yassine, Franziska Schmidt, Wolfgang Hannak, Bahadır Ersu

Zitieren

APA

Sözen Yanik, İ., Adali, U., Yassine, J., Schmidt, F., Hannak, W., & Ersu, B. (2025). Novel nonmagnetic abutment designs for facial prostheses: an experimental study. Turkish Journal of Medical Sciences, 55(1), 152-160. https://doi.org/10.55730/1300-0144.5953

Vancouver

Sözen Yanik İ, Adali U, Yassine J, Schmidt F, Hannak W, Ersu B. Novel nonmagnetic abutment designs for facial prostheses: an experimental study. Turkish Journal of Medical Sciences. 2025;55(1):152-160. doi:10.55730/1300-0144.5953

BibTeX
@article{SzenYanik2025,
  author = {Sözen Yanik, İrem and Adali, Ufuk and Yassine, Jamila and Schmidt, Franziska and Hannak, Wolfgang and Ersu, Bahadır},
  title = {Novel nonmagnetic abutment designs for facial prostheses: an experimental study},
  journal = {Turkish Journal of Medical Sciences},
  year = {2025},
  volume = {55},
  number = {1},
  pages = {152--160},
  doi = {10.55730/1300-0144.5953}
}
Kostenlos starten →