Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures
Acta Orthopaedica et Traumatologica Turcica · 2024
DOI: 10.5152/j.aott.2024.24076 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Acta Orthopaedica et Traumatologica Turcica, 2024. Verfasst von Yilmaz Onder und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Izmir Katip Celebi University, Ataturk Training and Research Hospital, Izmir, Türkiye. Hauptthemen laut MEDLINE: Femoral Neck Fractures, Bone Plates, Bone Screws, Fracture Fixation, Internal. Die Arbeit wurde bisher 6-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objective
The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.
Methods
A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models. The models were randomly divided into 4 groups, each containing 7 bones each. The bone fracture models were fixed with 3 parallel cannulated screws in group 1, 3 parallel cannulated screws combined with a medial buttress plate in group 2, LFNP in group 3, LFNP combined with a medial buttress plate in group 4. The stability of the specimens was tested biomechanically at a 7° valgus inclination to simulate normal 2-legged weight-bearing through an anatomical femur. The forces corresponding to 0.5 mm, 1 mm, 1.5 mm, and 2 mm displacement and failure loads were calculated in all groups.
Results
The axial load values corresponding to 4 di!erent fracture displacements and the failure load values of the groups were compared, group 1 was significantly weaker (P < .05 for each) while group 4 was significantly stronger (P < .05 for each) compared to the other groups. There was no statistically significant di!erence between group 2 and group 3 (P > .05 for each).
Conclusion
The results of this biomechanical study showed that the LFNP fixation system provided su"cient biomechanical stability for unstable Pauwels type 3 femoral neck fractures. The biomechanical performance of LFNP was similar to that of cannulated screws with medial buttress plate and better than that of cannulated screws alone. This suggests that LFNP can be a promising stable alternative fixation method to cannulated screws with a medial buttress plate in unstable femoral neck fractures Cite this article as: Onder Y, Bulut T, Eroglu O.N., Ciklacandir S, Isler Y. Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures. Acta Orthop Traumatol Turc., 2024;58(6):313-317
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics and Traumatology, Izmir Katip Celebi University, Ataturk Training and Research Hospital, Izmir, Türkiye.
- Department of Biomedical Engineering, Izmir Katip Celebi University Faculty of Engineering and Architecture, Izmir, Türkiye.
Zitieren
APA
Onder, Y., Bulut, T., Eroglu, O. N., Ciklacandir, S., & Isler, Y. (2024). Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures. Acta Orthopaedica et Traumatologica Turcica. https://doi.org/10.5152/j.aott.2024.24076
Vancouver
Onder Y, Bulut T, Eroglu ON, Ciklacandir S, Isler Y. Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures. Acta Orthopaedica et Traumatologica Turcica. 2024. doi:10.5152/j.aott.2024.24076
BibTeX
@article{Onder2024,
author = {Onder, Yilmaz and Bulut, Tugrul and Eroglu, Osman Nuri and Ciklacandir, Samet and Isler, Yalcin},
title = {Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures},
journal = {Acta Orthopaedica et Traumatologica Turcica},
year = {2024},
doi = {10.5152/j.aott.2024.24076}
}
EUVIMED