EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Biomechanical comparison of inverted triangle and L-shaped screw configurations with medial buttress and anteromedial support plate in Pauwels type III femoral neck fractures

Murat Erem, Utku Demirtaş, Savaş Yıldırım, Eşref Selçuk, Cem Çopuroğlu

Archives of Orthopaedic and Trauma Surgery · 06.06.2026 · 146 (1)

DOI: 10.1007/s00402-026-06352-x ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, online erschienen am 06.06.2026. Verfasst von Murat Erem und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Trakya University, Edirne, Turkey. muraterem@trakya.edu.tr. Hauptthemen laut MEDLINE: Bone Plates, Bone Screws, Femoral Neck Fractures, Fracture Fixation, Internal. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Trakya University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Surgical stabilization of Pauwels Type III femoral neck fractures remains a significant challenge due to high vertical shear forces. While the medial buttress plate is a recognized solution, it requires extensive deep dissection. This study aims to compare the biomechanical performance of various screw configurations combined with either a medial buttress or anteromedial support plate. Materials and methods Twenty-five third-generation synthetic femurs were used to create a standardized 70-degree (Pauwels III) fracture model. Specimens were divided into five groups ( n = 5): (A) Inverted triangle (IT) screws with a Pauwels screw, (B) Inverted triangle (IT) with medial buttress plate (MBP), (C) Inverted triangle with anteromedial support plate (ASP), (D) L-configuration with medial buttress plate (MBP), and (E) L-configuration with anteromedial support plate (ASP). Axial loading was applied at 2 mm/min until construct failure, defined objectively by the real-time force-distance curve.

Results

Although no statistically significant difference was found between groups ( p = 0.102), a large effect size was observed (η² = 0.309). Group C (IT + ASP) demonstrated the highest mean failure load (1695 ± 494.6 N). Conversely, Group E (L-configuration + ASP) exhibited the lowest stability (977.2 ± 195.4 N) with a remarkably narrow standard deviation. The majority of failures occurred as transverse subtrochanteric fractures distal to the implants.

Conclusion

The combination of an inverted triangle screw arrangement with an anteromedial support plate demonstrated comparable biomechanical stability to the medial buttress plate, while offering a potentially safer surgical corridor. Conversely, pairing L-shaped screw configurations with anteromedial support plates resulted in the lowest mean ultimate load-to-failure among the tested constructs, likely due to potential stress riser effects.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone PlatesBone ScrewsFemoral Neck FracturesFracture Fixation, InternalBiomechanical PhenomenaHumansProximal Femoral Fractures

Stichwörter der Autor:innen

Anteromedial support plateBiomechanical testingFemoral neck fractureInternal fixationMedial buttress platePauwels type III

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, Trakya University, Edirne, Turkey. muraterem@trakya.edu.tr.
  • Department of Orthopaedics and Traumatology, Sultan 1.Murat State Hospital, Edirne, Turkey. opdrutkudemirtas@gmail.com.
  • Department of Orthopaedics and Traumatology, Trakya University, Edirne, Turkey.

Förderung

  • Trakya University

Zitieren

APA

Erem, M., Demirtaş, U., Yıldırım, S., Selçuk, E., & Çopuroğlu, C. (2026). Biomechanical comparison of inverted triangle and L-shaped screw configurations with medial buttress and anteromedial support plate in Pauwels type III femoral neck fractures. Archives of Orthopaedic and Trauma Surgery, 146(1). https://doi.org/10.1007/s00402-026-06352-x

Vancouver

Erem M, Demirtaş U, Yıldırım S, Selçuk E, Çopuroğlu C. Biomechanical comparison of inverted triangle and L-shaped screw configurations with medial buttress and anteromedial support plate in Pauwels type III femoral neck fractures. Archives of Orthopaedic and Trauma Surgery. 2026;146(1). doi:10.1007/s00402-026-06352-x

BibTeX
@article{Erem2026,
  author = {Erem, Murat and Demirtaş, Utku and Yıldırım, Savaş and Selçuk, Eşref and Çopuroğlu, Cem},
  title = {Biomechanical comparison of inverted triangle and L-shaped screw configurations with medial buttress and anteromedial support plate in Pauwels type III femoral neck fractures},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2026},
  volume = {146},
  number = {1},
  doi = {10.1007/s00402-026-06352-x}
}
Kostenlos starten →