EUVIMEDEUVIMED entdecken
Crossref

Reliability and minimal detectable change of the Step Test in patients with knee osteoarthritis

Abdurrahman Nalbant, Bayram Unver, Vasfi Karatosun

Physiotherapy Quarterly · 29.03.2022 · 30 (1) · 14-17

DOI: 10.5114/pq.2020.102160 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiotherapy Quarterly, online erschienen am 29.03.2022. Verfasst von Abdurrahman Nalbant und 2 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The study aim was to evaluate the test-retest reliability and minimal detectable change of the Step Test in patients with knee osteoarthritis.

Methods

The intraclass correlation coefficient was used to assess the test-retest reliability of the Step Test. The minimal detectable change with 95% confidence interval (MDC95) was calculated to determine the true change. The inclusion criteria involved a diagnosis of knee osteoarthritis and age of ≥ 40 years.

Results

Thirty-eight participants who met the inclusion criteria were investigated. Seven were male and the mean age equalled 61.23 ± 9.31 years. Three patients had radiographic findings indicative of Kellgren-Lawrence grade II, 10 of grade III, and 25 of grade IV. The Step Test presented excellent test-retest reliability. The intraclass correlation coefficient was 0.97, standard error of the mean was 0.46, and the MDC95 was 1.27.

Conclusions

The Step Test is a reliable outcome measurement for the assessment of balance in patients with knee osteoarthritis, and it showed excellent test-retest reliability in these patients. The test may assist clinicians and researchers in evaluating balance and planning rehabilitation in patients with knee osteoarthritis.

Zitieren

APA

Nalbant, A., Unver, B., & Karatosun, V. (2022). Reliability and minimal detectable change of the Step Test in patients with knee osteoarthritis. Physiotherapy Quarterly, 30(1), 14-17. https://doi.org/10.5114/pq.2020.102160

Vancouver

Nalbant A, Unver B, Karatosun V. Reliability and minimal detectable change of the Step Test in patients with knee osteoarthritis. Physiotherapy Quarterly. 2022;30(1):14-17. doi:10.5114/pq.2020.102160

BibTeX
@article{Nalbant2022,
  author = {Nalbant, Abdurrahman and Unver, Bayram and Karatosun, Vasfi},
  title = {Reliability and minimal detectable change of the Step Test in patients with knee osteoarthritis},
  journal = {Physiotherapy Quarterly},
  year = {2022},
  volume = {30},
  number = {1},
  pages = {14--17},
  doi = {10.5114/pq.2020.102160}
}