EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Test-retest reliability and the minimal detectable change of clinical and structural outcomes in athletes with patellar tendinopathy

Mikkel Holm Hjortshoej, Syed Zahra Gillani, René Brüggebusch Svensson, S Peter Magnusson, Anne-Sofie Agergaard

Physical Therapy in Sport · 2026-11 · 82 · 101997

DOI: 10.1016/j.ptsp.2026.101997 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical Therapy in Sport, 2026-11. Verfasst von Mikkel Holm Hjortshoej und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Sports Medicine Copenhagen, Department of Orthopedic Surgery, Copenhagen University Hospital - Bispebjerg and Frederiksberg, Copenhagen,…. Hauptthemen laut MEDLINE: Tendinopathy, Patellar Ligament. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To establish test-retest reliability and minimal detectable change (MDC) values for outcomes in patients with patellar tendinopathy. DESIGN: Test-retest reliability study. SETTING: Hospital. PARTICIPANTS: Thirty participants (29.6 years, 77% males) underwent two test days with a 7-day hiatus. MAIN OUTCOME MEASURES: Single-leg decline squat (SLDS), VISA-P, pain pressure threshold (PPT), and ultrasound measurements (tendon thickness and Power Doppler (PD) activity). Data was analyzed using intraclass correlation coefficient (ICC) and MDC performed on standard deviation (SD) of pooled and change scores. RESULTS: The SLDS showed ICC values ranging from 0.86 to 0.92 with a MDC95 ranging from 0.91 to 2.46 on the numeric rating scale for SDchange and SDpooled. For the VISA-P, the ICC was 0.93 with a MDC95 of 6.05 and 11.81 for SDchange and SDpooled. PPT resulted in an ICC of 0.91 and MDC95 of 69.37 and 117.06 kPa for SDchange and SDpooled. Tendon thickness showed an ICC of 0.98 and MDC95 of 0.29 and 1.01 mm for SDchange and SDpooled. PD activity showed an ICC of 0.80, and MDC95 of 11.95 and 18.78 mm2 for SDchange and SDpooled. CONCLUSIONS: The SLDS, VISA-P, PPT, tendon thickness, and PD activity demonstrated good-to-excellent relative reliability in individuals with PT; however, absolute measurement precision was limited.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TendinopathyPatellar LigamentHumansReproducibility of ResultsMaleAdultFemaleYoung AdultAthletesPain ThresholdUltrasonographyPain Measurement

Stichwörter der Autor:innen

Functional testPatella tendonPsychometrics propertiesTendinopathy

Autor:innen und Institutionen

  • Institute of Sports Medicine Copenhagen, Department of Orthopedic Surgery, Copenhagen University Hospital - Bispebjerg and Frederiksberg, Copenhagen, Denmark; Center for Healthy Aging, Department of Clinical Medicine, U…

Zitieren

APA

Hjortshoej, M. H., Gillani, S. Z., Svensson, R. B., Magnusson, S. P., & Agergaard, A. S. (2026). Test-retest reliability and the minimal detectable change of clinical and structural outcomes in athletes with patellar tendinopathy. Physical Therapy in Sport, 82, 101997. https://doi.org/10.1016/j.ptsp.2026.101997

Vancouver

Hjortshoej MH, Gillani SZ, Svensson RB, Magnusson SP, Agergaard AS. Test-retest reliability and the minimal detectable change of clinical and structural outcomes in athletes with patellar tendinopathy. Physical Therapy in Sport. 2026;82:101997. doi:10.1016/j.ptsp.2026.101997

BibTeX
@article{Hjortshoej2026,
  author = {Hjortshoej, Mikkel Holm and Gillani, Syed Zahra and Svensson, René Brüggebusch and Magnusson, S Peter and Agergaard, Anne-Sofie},
  title = {Test-retest reliability and the minimal detectable change of clinical and structural outcomes in athletes with patellar tendinopathy},
  journal = {Physical Therapy in Sport},
  year = {2026},
  volume = {82},
  pages = {101997},
  doi = {10.1016/j.ptsp.2026.101997}
}
Kostenlos starten →