Measurement properties of the SARC-T: test-retest reliability, agreement and minimal detectable change in older adults with sarcopenia

Blanca Pedauyé-Rueda, José Luis Maté-Muñoz, Juan Hernández-Lougedo, Cristian Solís-Mencía, Rebeca Bueno-Fermoso, Arturo Cano-Uceda, Cristina Ojedo-Martín, Pablo García-Fernández

Frontiers in Aging · 29.05.2026 · 7

DOI: 10.3389/fragi.2026.1822206 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Aging, online erschienen am 29.05.2026. Verfasst von Blanca Pedauyé-Rueda und 7 weiteren Autor:innen. Beteiligte Einrichtung: HM Faculty of Health Sciences, Camilo José Cela University, Madrid, Spain. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The Sarcopenia Optoelectronic Chair-Rise Velocity Test (SARC-T) has been proposed as an instrumented chair-rise measure related to physical function in sarcopenia; however, its test-retest measurement properties have not been established. This study evaluated the test-retest reliability, agreement, measurement error and minimal detectable change at the 95% confidence level (MDC95) of the SARC-T in older adults with sarcopenia.

Methods

An observational methodological test-retest study was conducted in 55 institutionalized older adults with sarcopenia diagnosed according to EWGSOP2 criteria. The SARC-T was assessed in two sessions separated by 5 days under standardized conditions. The primary outcome was the best mean propulsive velocity recorded during the concentric phase. Test-retest reliability was assessed using ICC (3,1), Lin’s concordance correlation coefficient (CCC), standard error of measurement (SEM), MDC95, Bland–Altman analysis, and a linear mixed-effects model.

Results

Test-retest reliability was high (ICC = 0.93, 95% CI 0.88–0.96; CCC = 0.93, 95% CI 0.86–0.96). Measurement error was low (SEM = 0.017 m/s), and MDC95 was 0.05 m/s. Bland–Altman analysis showed a small but statistically significant mean bias of +0.008 m/s (p = 0.015), with 95% limits of agreement from −0.042 to +0.058 m/s, and additional analysis showed statistically significant proportional bias (slope = 0.161; p = 0.009). A small systematic session effect was also observed in the mixed-effects model (β = +0.008 m/s; 95% CI 0.002–0.018; p = 0.012).

Conclusion

Under the standardized conditions of the present protocol, the SARC-T showed high test-retest reliability and low measurement error; however, the presence of statistically significant mean and proportional bias indicates that agreement is not fully uniform across the measurement range and should be interpreted with caution, particularly at the individual level. The MDC95 may help interpret whether longitudinal changes in mean propulsive velocity are likely to exceed measurement-related fluctuation. These findings should be considered within the context of this specific population of institutionalized older adults with sarcopenia.

Schlagwörter

Stichwörter der Autor:innen

SARC-Tagingassessmentreliabilitysarcopenia

Autor:innen und Institutionen

  • HM Faculty of Health Sciences, Camilo José Cela University, Madrid, Spain.
  • HM Hospitals Health Research Institute, Madrid, Spain.
  • Department of Physiotherapy, Complutense University of Madrid, Madrid, Spain.
  • Department of Medicine, Faculty of Health Sciences, University of Deusto, Bilbao, Bizkaia, Spain.
  • Department of Nursing, Complutense University of Madrid, Madrid, Spain.
  • Faculty of Health Sciences, Alfonso X El Sabio University, Madrid, Spain.

Zitieren

APA

Pedauyé-Rueda, B., Maté-Muñoz, J. L., Hernández-Lougedo, J., Solís-Mencía, C., Bueno-Fermoso, R., Cano-Uceda, A., Ojedo-Martín, C., & García-Fernández, P. (2026). Measurement properties of the SARC-T: test-retest reliability, agreement and minimal detectable change in older adults with sarcopenia. Frontiers in Aging, 7. https://doi.org/10.3389/fragi.2026.1822206

Vancouver

Pedauyé-Rueda B, Maté-Muñoz JL, Hernández-Lougedo J, Solís-Mencía C, Bueno-Fermoso R, Cano-Uceda A, et al. Measurement properties of the SARC-T: test-retest reliability, agreement and minimal detectable change in older adults with sarcopenia. Frontiers in Aging. 2026;7. doi:10.3389/fragi.2026.1822206

BibTeX
@article{PedauyRueda2026,
  author = {Pedauyé-Rueda, Blanca and Maté-Muñoz, José Luis and Hernández-Lougedo, Juan and Solís-Mencía, Cristian and Bueno-Fermoso, Rebeca and Cano-Uceda, Arturo and Ojedo-Martín, Cristina and García-Fernández, Pablo},
  title = {Measurement properties of the SARC-T: test-retest reliability, agreement and minimal detectable change in older adults with sarcopenia},
  journal = {Frontiers in Aging},
  year = {2026},
  volume = {7},
  doi = {10.3389/fragi.2026.1822206}
}
Kostenlos starten →