EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

The efficacy of different implant surface decontamination methods using spectrophotometric analysis: an in vitro study

Roberto Giffi iD, Davide Pietropaoli iD, Leonardo Mancini iD, Francesco Tarallo iD, Philipp Sahrmann iD, Enrico Marchetti iD

Journal of Periodontal & Implant Science · 2023 · 53 (4) · 295

DOI: 10.5051/jpis.2203500175 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Periodontal & Implant Science, 2023. Verfasst von Roberto Giffi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Life, Health and Environmental Sciences, University of L'Aquila, L'Aquila, Italy. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Various methods have been proposed to achieve the nearly complete decontamination of the surface of implants affected by peri-implantitis. We investigated the in vitro debridement efficiency of multiple decontamination methods (Gracey curettes [GC], glycine air-polishing [G-Air], erythritol air-polishing [E-Air] and titanium brushes [TiB]) using a novel spectrophotometric ink-model in 3 different bone defect settings (30°, 60°, and 90°). METHODS: Forty-five dental implants were stained with indelible ink and mounted in resin models, which simulated standardised peri-implantitis defects with different bone defect angulations (30°, 60°, and 90°). After each run of instrumentation, the implants were removed from the resin model, and the ink was dissolved in ethanol (97%). A spectrophotometric analysis was performed to detect colour remnants in order to measure the cumulative uncleaned surface area of the implants. Scanning electron microscopy images were taken to assess micromorphological surface changes. RESULTS: Generally, the 60° bone defects were the easiest to debride, and the 30° defects were the most difficult (ink absorption peak: 0.26±0.04 for 60° defects; 0.32±0.06 for 30° defects; 0.27±0.04 for 90° defects). The most effective debridement method was TiB, independently of the bone defect type (TiB vs. GC: P

Schlagwörter

Stichwörter der Autor:innen

Air flowBrushDecontaminationGracey curetteImplantPeri-implantitisSurgicalUltrasonic scaler

Autor:innen und Institutionen

  • Department of Life, Health and Environmental Sciences, University of L'Aquila, L'Aquila, Italy.
  • Center for clinical Research and evidence synthesis In oral TissuE RegeneratION (CRITERION), Boston, MA, USA. mancinileonardo94@gmail.com.
  • Clinic of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.

ORCID-Profile: Roberto Giffi, Davide Pietropaoli, Leonardo Mancini, Francesco Tarallo, Philipp Sahrmann, Enrico Marchetti

Zitieren

APA

Giffi, R., Pietropaoli, D., Mancini, L., Tarallo, F., Sahrmann, P., & Marchetti, E. (2023). The efficacy of different implant surface decontamination methods using spectrophotometric analysis: an in vitro study. Journal of Periodontal & Implant Science, 53(4), 295. https://doi.org/10.5051/jpis.2203500175

Vancouver

Giffi R, Pietropaoli D, Mancini L, Tarallo F, Sahrmann P, Marchetti E. The efficacy of different implant surface decontamination methods using spectrophotometric analysis: an in vitro study. Journal of Periodontal & Implant Science. 2023;53(4):295. doi:10.5051/jpis.2203500175

BibTeX
@article{Giffi2023,
  author = {Giffi, Roberto and Pietropaoli, Davide and Mancini, Leonardo and Tarallo, Francesco and Sahrmann, Philipp and Marchetti, Enrico},
  title = {The efficacy of different implant surface decontamination methods using spectrophotometric analysis: an in vitro study},
  journal = {Journal of Periodontal & Implant Science},
  year = {2023},
  volume = {53},
  number = {4},
  pages = {295},
  doi = {10.5051/jpis.2203500175}
}
Kostenlos starten →