A COMPARATIVE STUDY TO ASSESS THE EFFICACY OF DIFFERENT METHODS FOR THE RETRIEVAL OF FRACTURED IMPLANT ABUTMENT SCREW: AN IN VITRO STUDY
Genetics and Molecular Research · 27.07.2026
DOI: 10.4238/z7vjt084 ↗Kurz gefasst
Fachartikel in der Zeitschrift Genetics and Molecular Research, online erschienen am 27.07.2026. Verfasst von Dr. Shitij Srivastava und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
Introduction
Fractured implant abutment screws represent a significant mechanical complication in implant dentistry and can compromise prosthetic stability, implant longevity, and treatment outcomes. Retrieval of fractured screws is a technically demanding procedure that requires effective removal while preserving implant integrity. Several retrieval techniques have been proposed; however, evidence regarding the most efficient and reliable method remains limited.
Aim
To comparatively assess the efficacy of different methods for retrieval of fractured implant abutment screws in an in vitro setting. Materials and Methods: A total of 108 implant specimens embedded in acrylic blocks were included in this in vitro experimental study and equally divided into three groups (n=36): Group I—Claw-Type Retrieval Kit, Group II—Reverse Drilling Retrieval Kit, and Group III—Conventional Hand Instrumentation. Fracture morphologies (ASF-1, ASF-2, and ASF-3) were equally distributed among all groups. Outcome variables evaluated included retrieval success rate, number of attempts required, retrieval time, and implant thread integrity following retrieval. Data were statistically analyzed using SPSS version 21.0. Chi-square test, one-way ANOVA, and Tukey post hoc analysis were applied, with p
Zitieren
APA
Srivastava, D. S., Srivastava, D. A., Shekhar, D. A., Chaturvedi, D. A., & Singh, D. A. (2026). A COMPARATIVE STUDY TO ASSESS THE EFFICACY OF DIFFERENT METHODS FOR THE RETRIEVAL OF FRACTURED IMPLANT ABUTMENT SCREW: AN IN VITRO STUDY. Genetics and Molecular Research. https://doi.org/10.4238/z7vjt084
Vancouver
Srivastava DS, Srivastava DA, Shekhar DA, Chaturvedi DA, Singh DA. A COMPARATIVE STUDY TO ASSESS THE EFFICACY OF DIFFERENT METHODS FOR THE RETRIEVAL OF FRACTURED IMPLANT ABUTMENT SCREW: AN IN VITRO STUDY. Genetics and Molecular Research. 2026. doi:10.4238/z7vjt084
BibTeX
@article{Srivastava2026,
author = {Srivastava, Dr. Shitij and Srivastava, Dr. Akshat and Shekhar, Dr. Abhinav and Chaturvedi, Dr. Anshuman and Singh, Dr. Abhishek},
title = {A COMPARATIVE STUDY TO ASSESS THE EFFICACY OF DIFFERENT METHODS FOR THE RETRIEVAL OF FRACTURED IMPLANT ABUTMENT SCREW: AN IN VITRO STUDY},
journal = {Genetics and Molecular Research},
year = {2026},
doi = {10.4238/z7vjt084}
}
EUVIMED