EUVIMEDEUVIMED entdecken
Crossref

Influence of Optional Biometric Variables on Refractive Outcomes Predicted Through the Barrett Universal II Formula

Telmo Cortinhal, Pereira, Pedro, Nuno Miguel Sousa Gouveia, Inês Figueiredo, Raimundo, Miguel, Lobo, Conceição, Joaquim Murta

Oftalmologia · 15.10.2023

DOI: 10.48560/rspo.33244 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Oftalmologia, erschienen am 15.10.2023. Verfasst von Telmo Cortinhal und 9 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Modern intraocular lens (IOL) calculation formulas depend on a set of mandatory biometric parameters – axial length (AL), keratometry, anterior chamber depth (ACD) – as well as optional biometric parameters. The Barrett Universal II (BUII) formula considers two optional parameters - lens thickness (LT) and white-to-white distance (WTW). These parameters may not be measurable using older optical biometry devices, and there is currently a lack of evidence regarding their effect on refractive outcomes. We compared refractive outcomes of uncomplicated cataract surgery with and without the use of optional parameters. METHODS: Retrospective consecutive case study of eyes that underwent uncomplicated cataract surgery with single piece monofocal IOL implantation (Alcon Acrysof SN60AT). We compared the predicted spherical equivalent (SE) for the implanted lens obtained through the BUII formula, with and without optional parameters, to the postoperative SE obtained by subjective refraction performed 6-12 weeks post-operatively. The primary outcome variable was the absolute prediction error (AE) evaluated by the median (MedAE) and interquartile range (IQR). A multivariate logistic regression model for the odds of improving the predictions was fitted with biometric variables. RESULTS: We included 1346 eyes with mean AL 23.36±1.08 mm (20.87-29.73), ACD 3.32±0.39mm (2.12-4.36), mean anterior keratometry 44.10±1.54D (38.48-49.63), LT 4.59±0.42 mm (3.12-6.00) and WTW 11.85±0.41 mm (10.51-13.36). After optimization, the median AE with optional parameters was significantly lower than without (with optional: MedAE 0.283D, IQR 0.310; without 0.289, IQR 0.326; p=0.005). The postoperative SE prediction changed by more than 0.1D (absolute values) in 26.15% (n=352). In this subset, a more accurate prediction was seen in 44.9% of cases (n=158), notably with lower LT (LT 12.67 or < 11.03, 2SD cutoff, OR 3.43, p=0.007). CONCLUSION: In our sample, the inclusion of optional biometric variables in the Barrett UII formula significantly improved outcomes. A greater benefit was observed for lower-than-average pre-operative LT and extreme pre-operative WTW.

Schlagwörter

Barrett Universal II formulaintraocular lens power calculationcataract surgeryrefractive outcome predictionlens thicknesswhite-to-white distancespherical equivalentprediction errormonofocal intraocular lensoptical biometry

Zitieren

APA

Cortinhal, T., Pereira, Pedro, Gouveia, N. M. S., Figueiredo, I., Raimundo, Miguel, Lobo, Conceição, & Murta, J. (2023). Influence of Optional Biometric Variables on Refractive Outcomes Predicted Through the Barrett Universal II Formula. Oftalmologia. https://doi.org/10.48560/rspo.33244

Vancouver

Cortinhal T, Pereira, Pedro, Gouveia NMS, Figueiredo I, Raimundo, et al. Influence of Optional Biometric Variables on Refractive Outcomes Predicted Through the Barrett Universal II Formula. Oftalmologia. 2023. doi:10.48560/rspo.33244

BibTeX
@article{Cortinhal2023,
  author = {Cortinhal, Telmo and Pereira and Pedro and Gouveia, Nuno Miguel Sousa and Figueiredo, Inês and Raimundo and Miguel and Lobo and Conceição and Murta, Joaquim},
  title = {Influence of Optional Biometric Variables on Refractive Outcomes Predicted Through the Barrett Universal II Formula},
  journal = {Oftalmologia},
  year = {2023},
  doi = {10.48560/rspo.33244}
}
Kostenlos starten →